NYC 9/11 Public Portal Document
ATC Environmental, Inc.
104 East 25th Street
New York, New York 10010
N.Y.C. Board of Education Approved N.Y. Stace ELAP #10879
28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187
Long Island City, NY lllCl Report Date; 10/27/01
ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM)
With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive K-RAY Spectroscopy :EDS',
Method; AHEEA Final Rule, FP;. Federal Register (40 CFR, Part 763), Vol. 52, No, 210, October 30, 1987
Sample Ideiitificacion Analysis Parameters
Project/Sit.e: New Stuyvesant R.S., 34 5 Chambers St., NY, NY TEM Sample Ho.: 5775 - 62376
Exterior & Inceriox- of Building & Roof
Date Received : l(.i/26/01 Grid Openings Analyzed:__ 4
Project Sample No.: IS Average Grid Opening
Air Volume: 1944 Total Area Tknalvzed: 0.04 5 0 mm2
Filtei Type-. MCE 25 mm dram Pore Size: 0.45 um Analytical Sensitivity:^22^2 s/miT^
Effective Area 385 mm2 C.Q044 s/cc
FIBROUS PARTICULATES ANALYZED
Number Observed CONCENTRATION
Total
Single Matrix Total. Struct. Filter Air
Fibers Bundles Clusters Struct. Struct >=5um Struct/mm2 Struct/cc nam/mS
Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Amphibole Asbestos 0 C 0 0 0 0 0. c 0.0000 0
Ambigucus 0 0 0 0 0 0 0.0 C . 0000 0
Total asbettcs (includes ambicuous structures) 0 0 0.0 0 . C000 0
Ncr.-Asbestcs 0 0 0 0 0 0 0.0 0.0000 N/A
No Identification 0 0 0 0 0 0 0.0 0.0000 N/A
Totals (All Structures) 0 0 0.0 0.0000 N/A
The estimated uncertainty of this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED); None detected
Amphibole Asbestos Type: None detected
The Analysis was carried out in accordance with the approved TEM method.
This laboratory is in compliance with the quality specified for the method.