NYC 9/11 Public Portal Document
ATC Environmental, Inc.
104 East 25th Street
New York, New York 10010
N.Y.C. Board of Education Approved N.Y. State ELAP #10879
28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187
Long Island. City, NY 11101 Report Date: 10/27/01
ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY [TEM]
With Fiber Idencification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS)
Method: ^HERA Final Rule, SPA Federal Register (40 CFP., Part 763), Vol. 52, No. 210, October 30, 1987
Sample Identification Analysis Parameters
Project/Site: Nev 5tu\nzesant H,5., 345 Chambers St., NY, NY TEM Sample No.: 5775 62368
Exterior k Interror of Building & Roof
Date Received: 10/26/^ Grid Openings Analyzed;__ 4
Project Sample No.: 7 Average Grid Opening: 1C6 . 00 um
Air Volume : 1928 irt^; Total Area Analyzed : 0;C£50 jnm2
Filter Type: MCE 25 mm diam., Pore Size: 0.45 um .Analytical Sensitivity: 22.2 s/mm2
Effective 7yre a : 3R5 mm2 0.0044 s/cc
FIBROUS PARTICULATES ANALYZED
Number Observed CONCENTRATION
Total
Single Matrix Total. Struct. Filter Air
Fiberc Bundles Clusters Struct. Struct Struct/miTi2 Struct/cc nqm/rr.5
Chrysotile Asbestos 0 D 0 0 0 0 0.0 o.oooc 0
Amphibole Asbestos 0 0 0 0 0 0 0.0 o.oooc 0
Ambiguous u 0 0 0 0 0 0.0 0.oooc c
Total asbestos (includes arJoiguous structures) 0 0 0.0 0,0000 0
Non-Asbestos 0 0 0 c 0 0 0.0 o.ouuc N/A
No Identification 0 0 0 0 0 0 0.0 0.0000 N/A
Totals (All Structures) 0 0 0.0 0.0000 N/A
The estimated uncertainty of Chis analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED): None detected
Amphibole Asbestos Type: None detected
The -Analysis weis carried out in accordance with the approved TEM method.
This laboratory is in compliance with the quality specified for the method.
Analyzed by: Report Reviewed by:
Marek Peysakhov Michael A. Gorycki, Ph.D.
Director of Electron Microscopy