NYC 9/11 Public Portal Document
ATC Environmental, Inc.
104 East 25th Street
New York, New York 10010
N.Y.C. Board of Education Approved N.Y. State ELAP #10879
28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187
Long Island City, NY 11101 Report Date: 10/25/01
ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM)
With ?ib€'r Identification oy Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS)
Method; AHER7\ Final Rule, }1?A Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987
Sample Identification Aria 12/sisParamet^rs
?roject/Siie: New Stuyvesant H.S., 345 Chambers St., NY, NY TEM Sample No.: 5766 62351
Exterior & Interior of Building & Roof
Date Received: 10/25/01 Grid Openings Analyzed:__4
Project Sample No.; 19 Average Grid Opening: 106.00 urn
Air Volumt? :192£liters Total Area Analyzed .C;04 50 m2:2
Filter Tyiie: MCE 25 mm diam. , Pore Size: 0.45 urn Analytical Sensitivity :22^2 s2mm2
Effective Area : 3e5nim2 0.0044 s/cc
FIBROUS PARTICULATES ANALYZED
Number Observed CONCENTRATION
Total
Single Matrix Total. Struct. Filter Air
Fibers Bundies Clusters Struct. Struct > = 5um Struct/mm2 Struct/cc nanri/mj
Chrysotile Asbestos 0 0 0 0 0 0 0.0 O.OCOO 0
Amphibole Asbestos 0 0 0 0 0 0 0. 0 0.0000 0
Ambiguous Cl 0 0 0 0 0 0.0 0.0000 0
Total asbestos (include-s amJiiguous structures) 0 0 0. 0 0.0000 0
Non-Asbestos 0 0 0 0 0 0,0 0.0000 N/A
No Identification C 0 0 0 0 0 0.0 0.0000 N./.A
Totals {All Structures) 0 0 0.0 0.0000 N/A
The estimated uncertainty ol tlxis analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED); None detected
Amphibole Asbestos Type: None detected
The Analysis was carried out in accordance with the approved TEM method.
This laboratory is in compliance with the quality specified for the method.
Analyzed by: Report Reviewed by:
Michael A. Gorycki, Ph.D. Michael A. Gorycki, Ph.D.
Director of Electron Microscopy
CONFIDENTIAL, CITY_21MC100_003473363
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000248292