ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/25/01

ASBESTOS FIBER /yNALYSISBYTRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: ivHERA Final Rule, EB’A Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987

Sample Ideir.tificacion Analysis Parameters

Project/Site; New Stuwesant H.S., 345 Chambers St., NY, NY TEM Sample No.: 5766 62345 Exterior ix Interior of Building & Roof Date Rece ived Grid Openings Analyzed:__ 4

Project Sample No.: 13 Average Grid Opening; 106.00 urn

Air Volurre :J,9j:6 l it^s Total Area Analyzed :0,J14 5 0 rnrr2

Filter Type; MCE 25 mm diam. Pere Size; 0.45 urn Analytical Sensitivity :22^2 s/rnm2 Effective Area: 385 mm2 3.0044 s/CC

FIB^'JSPARTICULATSSANALYZEP Number Observed CONCENTRATION Total Single Matrix Total. struct. Filter Air Fibers .Bundl^es___CUi5t^rs___St£uct_;__Str7Jct > = 5um Struct/ni'n2 Struct/cc nqm/fn3

Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Amphibole Asbestos 0 0 0 0 0 0 0. c 0.0000 0

Ambiguous 0 0 0 0 0 0 0.0 0.0000 0

Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0 Non>Asbestos 0 0 0 0 0 0 0.0 0.0000 N/'A No Identification 0 0 0 0 0 0 0.0 0.0000 N/A

Totals (All Structures; 0 0 0. 0 D.OOOC N/A The estimated uncertainty' cf this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected

The jlnalysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by:

Michael A. Gc-rycki, Ph.D. Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CONFIDENTIAL, CITY_21MC100_003473357 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000248289

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000248289Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000293857

Asbestos TEM analysis parameters for New Stuyvesant HS exterior/interior; Oct 2001.

Similar indexed content

NYC-WTC_000270917

TEM asbestos analysis including SAED/EDS data for New Stuyvesant H.S., received 10/27/01.

Similar indexed content

NYC-WTC_000270678

TEM analysis with SAED/EDS for New Stuyvesant H.S., Oct 2001.

Similar indexed content

NYC-WTC_000248381

TEM asbestos analysis with SAED/EDS for New Stuyvesant H.S., Oct 2001.

Similar indexed content

Compare copies and versions →