TEM asbestos analysis, Stuyvesant HS, Oct 2001

Machine-extracted title · confidence 33%

TEM analysis for New Stuyvesant High School, exterior/interior; sample 12 details.

NYC-WTC_000248288
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Screet New York, New York 10010

N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: lO/25/Ol

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fib€:r Identification oy Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method; AHE.RA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987

Samole Identification Analysis Parameters

Project/Si te: New Stu^^esant H.S., 345 Chambers St., NY, NY TEM Sample No.: 5766 62344 Exterior & Ii.tetiorct3uiJ^dinc 5RiJof Date Received; 10/25/01 Grid Openings Analyzed;__4

Project Sample No.: 12 Average Grid Opening: IOC.PC urn

Air Volume: 1944 liters Total Area Analyzed: 0.0450 mrr.2

Filter Type; MCE 25 mm diam.. Pore Size: 0.45 urn Analytical Sensitivity:22^.2 s/mrn2 Effective Area : .385 mm2 0.0044 s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct > = 5um Struct/'mm2 Struct/cc naTn/m3

Chi'ysotile' Asbestos G 0 0 0 0 0 0.0 0.0000 0

Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Ambiguous 0 0 0 0 0 0 0.0 0.0000 0

Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0 Non-Asbestos 0 0 0 0 0 0 0. 0 o.oooc N/A No Identification 0 0 0 c 0 0 0.0 0.0000 N/A

Totals (All Structures) 0 0 0. 0 0.0000 N/A The estimated uncertainly of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED); None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by; Report Reviewed by;

Michael A. Gorycki, Ph.D. Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CONFIDENTIAL, CITY_21MC100_003473356 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000248288

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000248288Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000270586

TEM asbestos analysis by SAED/EDS for air samples at New Stuyvesant High School.

Similar indexed content

Compare copies and versions →