TEM asbestos analysis, Stuyvesant HS, Oct 2001

Machine-extracted title · confidence 35%

TEM analysis details for Stuyvesant HS project; sample 6, opening, air volume.

NYC-WTC_000248283
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/25/01

ASBES70S FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AIIEP^A Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987

Sample I dent if LcaTior. Analysis Parameters

Project/Site -. New Stuyvesant H.S., 345 Chambers St., NY, NY TEM Sample No.: 5766 62338 Exterior & Irterior of Building & Roof Date .-received: 10/25/03 □rid Openings Analyzed:__ 4

Project Scimple No. : 6 Average Grid Opening :l££;0C^

Air Volume: 1928 liters Total Area Analyzed :0,.;0450 rTUTu

Filter Tyj)e: MCE 25 mm dian^., Pore Size: 0.45 urn Analytical Sensitivity:22^2 s/mm2 Effective Area: 385 mm2 0.0044 s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Totai. Struct. Filter Air Fibers Bundles Clusters Struct. Struct >=Sum Struct /mtr;2 Struct/cc nqm/m3

Chrysotile? Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 c

Ambiguous 0 0 0 0 0 0 0.0 0.0000 0

Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0 Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 K/A No Identification 0 0 0 0 0 0 0.0 0.0000 N/A

Totals (All Structures) 0 0 0.0 0.0000 N/A The estimetted uncertainty cf this analysis is 1 standard deviation

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by:

Michael A. Gcrycki, Ph.D. Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CONFIDENTIAL, CITY_21MC100_003473350 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000248283

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000248283Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000274118

TEM asbestos analysis with SAED/EDS at New Stuyvesant High School, Oct 2001.

Similar indexed content

NYC-WTC_000244442

TEM analysis with SAED/EDS for New Stuyvesant High School exterior/interior samples.

Similar indexed content

TEM asbestos analysis, 5784, 10/27/01

NYC-WTC_000248352

TEM analysis of asbestos sample 5784; New Stuyvesant HS; exterior/interior; SAED/EDS; received 10/27/01; analyzed 10/27/01.

Similar indexed content

Compare copies and versions →