NYC 9/11 Public Portal Document
ATC Environmental, Inc.
104 East 25th Street
New York, New York 10010
N.Y.C. Board of Education Approved N.Y. State ELAP #10879
28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187
Long Island City, NY 11101 Report Date; 10/25/01
ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM)
With Fiber Idencificat.ion by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS)
Method: ;J4ERA Final Rule, EFA Federal Register {4C CFR, Part 763), Vol. 52, No. 210, October 30, 1987
Sample Identification AnalvsisParamet^^
Project/Site: New Stuyvegant H.S., 345 Chambers St., NY, NY TEM Sample No.: 5766 62336
Exterior & Interior of Building & Roof
Date Received :l 02j252£l Grid Openings Analyzed:__ 4
Project Sample No.;_4 Average Grid Opening: 106.00 uiri
Air Volume ; 1926 2J^ter£; Total Area Analyzed: 0.0450 mm2
Filter Type: MCE 25 mm diam. Pore Size: 0.45 urn Analytical Sensitivity 22.2 s/mni2
Effective Are.^j: 385 mm2 C■0044 s/cc
FIBROUS PARTICULATES ANALYZED
Number Observed CONCENTRATION
Total
Single Matrix Total. Struct. Filter Air
Fibers Bundles Clusters Struct. Struct % = Rum Struct/mm2 Struct/cc ngm/m3
Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Ambiguous 0 0 0 0 0 0 0.0 0.0000 0
Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0
Non-Asbesl;os 0 0 0 0 0 0 0, 0 0.0000 N/A
No Identification C 0 0 0 0 C 0,0 0.0000 N/A
Totals (All Structures) 0 0 0.0 0 .0000 N/A
The estimated uncertainty cf this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED): None detected
Amphibole Asbestos Type: None detected
The Analysis was carried out in accordance with the approved TEM method.
This laboratory is in compliance with the quality specified for the method.
Ansilyzed by: Report Reviewed by:
Michael A. Gorycki, Ph.D. Michael A. Gorycki, Ph.D.
Director of Electron Microscopy