NYC 9/11 Public Portal Document
ATC Associates
104 East 25 Street, New York, NY 10010
Phone:(212) 353-8280 Fax:(212)353-8306
sure
Attn: Fred Burkhardt Received: 9/17/02 8:00:00 AM
ATC Associates Inc. ATC Group ft: 8847
104 East 25th Street Analysis Date: 9/19/02
New York NY 10010
Fax; (212) 353-3599 Phone: (212) 353-8280
Project: DEP Cleaan-up Project #: 22906-0002
125 Cedar Street, New York, NY
Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) Performed
by EPA 40 CFR Pan 763 Final Rule (AHERA)
Analytical Asbestos
Area Non Asbestos # Structures Sensitivity Concentration
Sa inpie i'oiaine Analyzed Ash Type(s) 0.5p-S Sp (S/cc) (S/min!) (S/cc) iS'otes
I 2400 00 0 0450 0 None Detected 0 0 0,0036 < 22.24 <0.0036
•Sts J ■' - /
2400.00 0 0450 0 . None Detected 0 0 0,0036 <22,24 <0,0036
8847 -2
r ■
2390,00 0,0450 0 None Detected 0 0 0,0036 <22.24 <0.0036
-5
4. .-■ 2390.00 0.0450 0 None Detected 0 0 0.0036 <22.24 <0.0036
8847' -4
5 2380.00 0.0450 0 None Detected 0 0 0.0036 <22.24 <0.0036
88'47 -5
6 2800.00 0.0450 0 None Detected 0 0 0.0031 <22.24 <0.0031
■8847 -6
7 0 None Detected
2800.00 0.0450 0 0 0.0031 <22.24 <0.0031
884'! .
MARK PEYSAKHOV MICHAEL A. GOR.YCK1, Ph.D
Analyzed by: Approved by
Disclaimer: The laboratory is not responsible for data reported in structures/cc, which is dependent on volume collected by non-laboratory personnel. This lab is only responsible
for data reported in structures/mml This report may not be reproduced, except in full, without written approval by ATC Associates Inc. This report may not be used to claim
product endorsement by NVLAP or any other agency of the U.S. Government. This 'eports relates only to the samples reported above. Quality control data (including 95°'o
confidence limits and laboratory and analysis' accuracy and precision) is available upon request.
.Accredited for NVLAP PlfATEM #101187-0. NY State Ei-AP #10879
Pape I 11/8
CONFIDENTIAL, CITY_21MC100_003446594
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000247947