NYC 9/11 Public Portal Document
Oxides of Mitrogen/
Sulfur: Sampling on grappler operators on the rubble pile, and on employees running truck
wash stations revealed trace levels of nitric oxide and nitrogen dioxide. iO; personal
and area results were found to be below OSHA limits.
Metals: OSHA has taken 653 air samples to monitor worker exposures to dusts, ftmes, oxides,
and other compounds of metals such as antimony, beryllium, chromium, cdralt. copper,
iron, lead, manganese, molybdenum, nickel, vanadium, zinc, cadmium, nagnesium,
arsenic, and mercury. Results from these samples are generally well below the
applicable OSHA limits. However, torch cutting and burning structural steel at the
rubble pile have resulted in instances of overexposures as follows; coppT (10); iron
oxide (21); lead (12); and cadmium (2). Accordingly, OSHA is recomitending that
workers engaged in these operations wear appropriate respiratory protection.
Ionizing Radiation; A survey of the rubble pile was conducted on 10/22-10/23 to check for latent radiation
with particular attention to alpha radiation. Preliminary results show no elevated levels.
Dioxins: OSHA has taken samples for dioxin and these samples were analyzed byEPA. One
initial sample, representing exposure directly on the pile, showed elevated levels of
dioxins when compared to ambient background levels. This value was comparable to
the levels found by EPA sampling. The dio.xins at this location are being emitted from
the on-going rubble fire. Additional sampling was conducted around the perimeter of
the pile and revealed levels that were considerably lower than those on the rubble pile.
Dioxins are considered collectively as suspect human carcinogens. OSHA does not
have a worker standard for dioxins. OSHA is coordinating with EPA, and the Salt
Lake City Analytical Laboratory to fully assess the risk posed by the elevated levels of
dioxins.
Polynuclear Aromatic
Hydrocarbons OSHA has taken 132 samples. The majority of the samples have not shovm the
presence of benzo(a)pyrene and/or one or more of five additional fused polycyclic
hydrocarbons: anthracene, acridine, pyrene, chrysene and phenanthrene. Sample
results to date have identified seven samples which reached or exceeded OSHA's coal
tar pitch volatile PEL of 0.2mg/ni^. These personal samples were taken on the pile on
iron workers and grappler operators. OSPIA continues to strongly recominend the use
of respiratory protection when working on the rubble pile.
Freon R-22,
Hydrogen Fluoride
& Phosgene: OSHA has taken 105 samples for Freon R-22 (chlorodiflouromethane). The majority of
sample results received to December 17'*’reveal non-detectable airborne levels. During
operations involving Freon removal from the auxiliary chiller that started on 12/5/01,
direct reading instrument revealed readings ranging from 100 ppm to one peak near a
leaky valve of 500 ppm. SCBA tanks were and are being worn by workers, and masks
are to be worn only when direct reading instruments reveal 850 ppm Freon and/'or less
than 20.4% Oxygen. OSHA does not have an exposure limit for Freon R-22. (The
NIOSH R£L for Freon is lOOOppm..) In response to information about exposure to the
decomposition by-products of Freon R-22 used in the air conditioning systems of WTC
towers, sampling for hydrofluoric acid (HF) had been conducted. Results for HF
revealed non-detectable levels. Sample results for phosgene to date show non-
detectable levels.
Page 2 of 2
CITY_21 MCI 00 014579981
NYC-WTC_000246757
OCR can misread numbers and units. Confirm readings against the page image before using them.