Table 1: Air sampling costs, NYC Law Department

Machine-extracted title · confidence 31%

Table listing air sampling analytical costs and workflow for Law Department.

NYC-WTC_000246068
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

TABLE 1 New York City Law Department Office of Corporation Counsel

Air and Settled Dust Sampling List of Analytes and Methods

Sample Hours for Total Cost per Sample Agency Volume Sample Rate Collecting Samples Samples Sample Extended Pollutant Substrate Method Standard Media Liters Liters/minute the Sample Lab per Floor (w/blanks) ($) Cost ($) Lead/Metals Air Sample NIOSH 7300 Various - Filter, -960 -2 8 PAS 5 34 180 6,120 depending on cassette and specific metal holder Surface Dust NIOSH 9100 HUD 40 ug/ft’ Ghost Wipe sq.ft. NA PAS 5 33 20 660 for Lead Only (floors) Mercury Air Sample NIOSH 6009 50 ug/m3 Hopcalite up to 100 -0.2 8 Galson 1 8 60 480 tube and prefilter Asbestos Air Sample NIOSH 7402 AHERA 70 Filter, -1200 -10 2 EMSL/Sci 10 67 65 4,355 s/mm^ cassette and Lab holder Surface Dust ASTM 5755 None Available - Filter, sq. ft. NA EMSL/Sci 5 33 110 3,630 case by case cassette and Lab basis holder Respirable Air Sample NIOSH 7500 OSHA PEL Filter, -800 -2.5 4 Galson 5 34 65 2,210 Silica Quartz based on % cassette, Dust’ holder and cyclone Respirable Air Sample NIOSH 0600 OSHA PEL 5.0 Filter, -375 -2.5 2.5 Galson 5 34 20 680 Particulates’ mg/m^ cassette, holder and cyclone VOCs Air Sample USEPA TO- Various - TD tub 100 PAS 1 8 270 2,160 15 depending on minutes specific volatile organic compound Polynuclear Air Sample USEPA TO Various - PUP up to 960 -2 8 Galson 1 8 245 1,960 Aromatic 13A depending on cartridge Hydrocarbons specific (Semi Volatile compound Organics)

PCBs Air Sample NIOSH 5503 NIOSH REL = Filter, up to 50 -0.1 8.3 Galson 1 8 80 640 0.001 mg/m’ cassette, holder and sorbent tube Surface Dust EPA 3500B Ghost Wipe sq. ft. NA Galson 2 22 80 1,600 Biological Air Sample PK100/ Variable Anderson -141.5 -28.9 P&K 3 16 165 2,640 (Fungi & PK102 Pump w/Petri Bacteria)’ dish sample media

Surface Swab PK103 Variable Swabs 10 cm^ NA P&K 3 75 750 Total 313 27,885

Notes ’ Silica Quartz (NIOSH 7500) and Respirible Nuisance Dust (NIOSH 0600) can be analyzed using the same filter media/sample. ’ For air samples, this includes a total of 9 samples as follows: Indoor: 3 fungi/floor (basement and sub-basmt) -r 3 bacteria/floor -r 2 blanks (1 fungi and 1 bact) Ambient: 1 fungi + 1 bacteria

NYC-WTC_000246068

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000246068Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

PS 89M lab report, 2002 · Box unavailable

NYC-WTC_000250241

Laboratory report page with OCR-garbled content; appears to be environmental test results related to PS 89M.

7 shared non-person entities · 1 shared topics · similarity 0.899

machine-extracted · confidence unavailable · Check page ↗

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000453476

Status and list of air sampling analyses; Office of Corporation Counsel, Feb 2002.

Similar indexed content

NYC-WTC_000453675

List of analytes and methods for air sampling in NYC Law Department projects; includes asbestos and metals targets.

Similar indexed content

Compare copies and versions →