NYC 9/11 Public Portal Document
Mr. Steve Thompson
October 24, 2001
Page 4
a low asbestos structure count as a result of NIOSH Method 7402 analysis correlates to the
absence of asbestos fibers. Asbestos structures smaller than the size counted in TEM
Method 7402 could still present a health risk. There is no known safe level of exposure to
airborne asbestos.
• Dust generation has been observed during off loading of debris, in particular when the
debris is dry. This, combined with the air sampling results to date, lead EE&G to
recommend that this area be designated an exclusion zone and included under the Health
and Safety Plan. Various dust suppression alternatives are currently being examined for
marine transfer operations. Until an effective dust suppression procedure can be put in
place, personal protective equipment will be the primary method of worker protection.
Consideration should be given to using a fine mist spray on loads that are dry, and/or in the
unloading storage bunkers. All workers in the immediate vicinity of the loading operations
should be wearing respiratory protection (OV/HEPA cartridge), Tyvek protective coveralls,
hard hats, steel-toed boots, safety goggles, and gloves. These workers should be required
to pass through a personal hygiene station (like at the top of the landfill) prior to taking lunch
breaks or going home for the day. As an exclusion zone, further monitoring of the
employees should be conducted.
• As per OSHA requirements, the results of the air sample data must be transmitted to the
effected employees, including all employees in the same job function, within 15 days of
receipt of the lab data. While the analysis of the samples (#’s 101701JF11 and
101701PH02) by TEM suggests that the fibers reported in the data from analysis by PCM
are not asbestos (note size limitations of analysis, as discussed above), the exceedance of
the OSHA PEL cannot be disregarded. EE&G recommends that both sets of data be
presented and explained to the affected individual(s). If requested, EE&G representative
will be available to assist the client in performing this task.
Please call us if you have any questions regarding this correspondence. As always, we are
ready to assist Pqillips & Jordan upon a moment’s notice.
Sincerely, I \
Jay W. Sall, C.I.H.
Seniqr Industrial Hygienist
EE&C
lothy R. Gipe
/’resident
EE&G
TRG/JWSjws
NYC-WTC_000246007
OCR can misread numbers and units. Confirm readings against the page image before using them.