TWA = (Ti X CJ + (Tg X Cg) + (Tg X Cg) + ...
480 Minutes
Where:
Ti = 367 minutes
Ci = 0.165 f/cc
T2 = 30 Minutes
C2 = 0.047 f/cc
TWA = 0.129 f/cc
• The 8-hour Time Weighted Average for this sample set, calculated using both samples from
this set, showed a value of 0.129f/cc.
• Sample # 101701JF11, which showed 0.165 f/cc when analyzed by PCM, yielded a
concentration of less than 0.004 f/cc when analyzed by Transmission Electron Microscopy
(TEM) utilizing NIOSH Method 7402. The laboratory analysis identified one asbestos fiber
in this sample.
• One of the fourteen sample sets contained a short duration sample (# 101701PH02), which
yielded a concentration of 0.123 f/cc when analyzed by PCM. Whole shift sampling could
not be obtained (sample overloaded, as mentioned above).
• The Short-Term Exposure Limit (STEL) result of 0.123 f/cc is below the limit established by
OSHA for the STEL and the other sample in the set that was representative of the
remainder of the work shift was overloaded. The STEL was presumed to be representative
of the whole shift exposure. Based on this presumption, the whole shift exposure would be
presumed to be above the PEL. The calculation is done with the same formula for the TWA
as presented above where C, =0.123 f/cc and Ti = is assumed to be 480 minutes.
• This same sample (#101701PH02), when analyzed by TEM using NIOSH Method 7402
identified no asbestos fibers.
• Pursuant to the request of DSNY, EE&G reviewed its notes regarding the DSNY “oiler” who
wore the sample in which the asbestos PEL was exceeded. EE&G’s field industrial hygiene
technician reported that the “oiler” was not wearing a respirator, when observed.
• The 0.129 f/cc result that was collected from the worker group “oiler” exceeded the OSHA
defined PEL.
Metals and Silica/Total Particulate
On October 17 and 19, EE&G collected air samples for metals and silica/total particulate from
DSNY workers performing the following job functions:
Dozer 003 operator, silica/total particulate.
Truck counter, silica/total particulate.