NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 3 pages

Air sample data summary, Staten Island WTC project, Apr 2002

Machine-extracted title · confidence 28%

Summary of air sample data collected for DSNY Staten Island WTC project on 4/23/02.

NYC-WTC_000246001–000246003
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

£00'399d iTS89968Ti VE:80 20. 20 AbW

Mr. William Garibay, CSP May 1. 2002 Page 2

CONCLUSIONS

Asbestos

None of the six samples collected in the time period covered by this report exceeded the OSHA PEL. All six samples had TWAs above the United States Environmental Protection Agency’s (USEPA) clean air standard of 0.01 f/cc. OSHA has an established PEL for asbestos of 0.1 f/cc measured as an 8-hour TWA, and an excursion limit of 1.0 f/cc measured over a 30-minute period. Approximately 20% of these PCM samples were analyzed by transmission electron microscopy (TEM) for quality control purposes. The results of the TEM analysis will be reported under separate cover.

Metals

None of the samples collected and analyzed for metals showed concentrations above the personal exposure limit.

Silica and Total Particulates

None of the samples collected and analyzed for silica and total particulates showed results which exceeded the personal exposure limit.

RECOMMENDATIONS

Based on the findings and conclusions presented above, EE&G recommends the following:

Air sample data should continue to be collected for the duration of the project. This is based on the exposure data, which suggests that some activities could result in exposures, as well as the non-homogeneous nature of the material being inspected, changing workforce, varying weather conditions, etc.

Employees working in or near the sorting and sifting areas should wear persona! protective equipment including half-face negative pressure respirators equipped with dual cartridge organic vapor and P-100'filters, and disposable protective clothing. Other hazards in the work area necessitate the use of protective clothing (Tyvek suits), hard hats, hearing protection, eye protection, and foot protection. Additionally, there may be other chemical substances contained in the debris and ash that are not being tested for frequently: consequently, continued use of the respiratory protection, as defined in the Health and Safety Plan, is recommended.

Workers should be informed of the results of the exposure monitoring described in this report. The attached spreadsheet can be used for this purpose, or EE&G can provide a different format, if requested.

0501dsny

NYC-WTC_000246002

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000246002Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read