Direct reading results summary, DSNY site

Machine-extracted title · confidence 57%

Summary of direct-reading instrument results for hazardous environments at DSNY site.

NYC-WTC_000245971–000245972
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

SUMMARY OF DIRECT READING RESULTS 10/24/01-10/25/01

Direct reading instruments were used to measure the concentration of potentially hazardous environments throughout the site. Specifically, surveys were performed on each shift for total volatile organic chemicals (TVOCs) using a hand held Photo- Ionization Detector (PID). This yielded results as parts per million (ppm) of organic vapors. A four-gas meter was used to measure hydrogen sulfide, oxygen, and carbon monoxide concentrations as well as explosive atmospheres. Chemical compounds were reported as ppm, and explosive atmospheres and oxygen were reported as percent (%) concentration and % of the lower explosive limit (LEL) respectively. As per the written health and safety plan (HASP), the action level for the LEL is 10%, For the purposes of this summary, the action level for hydrogen sulfide will be 16 of the Occupational Safety and Health Administration (OSHA) Ceiling limit, or 10 ppm, and 25 ppm for carbon monoxide. The minimal acceptable concentration of oxygen will be 19.5%.

Readings were taken from enclosed buildings as well as outside locations throughout the job site. In the event that a structure was locked, a reasonable effort was made to obtain entry. If entry could not be obtained, the structure was not surveyed. A summary of results for the time period stated above are presented below:

Carbon Monoxide

Approximately 30 areas were surveyed, including approximately 20 structures, and 10 outside locations.

No spot readings were above the action level, or the OSHA Permissible Exposure Limit (PEL) of 50 ppm.

Three locations had detectable readings of carbon monoxide which ranged from 1 ppm to 7 ppm. The reading of 7 ppm was found in the Building 7 open ended cover sprung structure. The other two readings of 1 ppm each were from the FBI portable and outside, near a generator in the Agency support area.

Hydrogen Sulfide

Approximately 30 areas were surveyed, including approximately 20 structures, and 10 outside locations.

No readings were above the action level of 16 of the OSHA ceiling, 10 ppm.

No readings above the detection limit of the instrument were found (1 ppm).

NYC-WTC_000245971

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000245971Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000354092

DOHMH memo detailing October 2001 air monitoring results for indoor contaminants.

Similar indexed content

NYC-WTC_000279307

Preliminary indoor air monitoring results for 225 Broadway floor near WTC site.

Similar indexed content

Compare copies and versions →