OSHA exposure tables, lab data

Machine-extracted title · confidence 60%

Tables of personal air samples exceeding OSHA PELs for exposure; details per sample.

NYC-WTC_000245943–000245964
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

TABLES-A

The following tables represents only personal air samples that have exceeded OSHA ‘PEL’s and Excursion Limit (or short­ term exposure limit)

Permissible Exposure Limit (PEL) is defined as the concentration that OSHA will allow a worker to breath before requiring respiratory protection. These limits are expressed for exposure durations-usually an 8-hour shift or full work shift. This means that for some work situation, a worker can be exposed to asbestos dust at a concentration of 0.1 f/cc over an 8-hour time-weighted average (TWA) without being required by OSHA to wear a respirator.

Excursion Limit (or short-term exposure limit) is a short term sample-30 minutes with a maximum concentration of 1 f/cc.

9/13/01 to 9/14/01: A total of 48 samples including field blanks were collected of which 9 samples were overloaded and 2 samples were voided. 6 samples indicated that OSHA PEL’S has exceeded 8-hour TWA of O.lf/cc, while the Excursion limit of 1 f/cc was not exceeded over a 30-minute period. All the other remaining samples did not exceed OSHA PEL’s.

SAMPLE SAMPLE NAME TASK VOL LOCATION TWA STEL (EL) COMPANY DATE (Liters) (f/cc) TAKEN 9/13/01 to TEG -1 382 L North of Ground ' 0.103 Yes TEG 9/14/01 TEG-3 60 L Zero TEG-5 450 L TEG-2 380 L North of Ground 0.109 Yes TEG TEG-4 60 L Zero TEG-6 480 L NOTE: The Personal Exposure monitoring Time Weighted Average (TWA) has exceeded the OSHA PEL’s limit for asbestos and requires the use of half-mask-air purifying HEPA filters at the minimum and may require a full face-piece- air-purifying/power respirator depending on the strenuous task and exposure.

NYC-WTC_000245943

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000245943Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →