IAQ memo, PS 89M, Warren Street, Jan 30, 2002

Machine-extracted title · confidence 28%

Indoor air measurements for PS 89M under BOE program.

NYC-WTC_000245394–000245397
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Mr. Bernard P. Orlan January 30, 2002 Indoor Air Quality Assessment Page 4 P. S. 89M ATC Project No. 15-19125-0297 concentration for the entire school building was approximately 38 ug'mY This average concentration was below the USEPA recommended concentration of 40 pg/m^ for sensitive

individuals such as asthmatic people and children. The outdoor respirable particulate concentration averaged 83 pg/m^ (A.M.) and 45 pg/m^ (P.M.).

* The measurements made during this assessment were instantaneous readings, the NP/KAQS is a 24-hour average.

TVOC Concentration

TVOCs were not detected (0.0 ppm) anywhere inside or outside the building.

OBSERVATIONS

During this assessment, ATC noted the following: • The interior of the building appeared clean and free of dust and debris; • The building was partially occupied at the time of the assessment; • No smoke odor was detected in the building.

FINDINGS

Based on the real-time measurements, the following findings are presented:

1. Concentrations of COp. CO and TVOCs were within applicable guidelines; 2. Fifty-eight (58) of sixty-four (64) measurements of temperature were within the recommended range; 3. Fifty-seven (57) of sixty-four (64) indoor measurements of relative humidity were within the recommended range; 4. Instantaneous readings of PMp s concentrations averaged below the NPAAQS of 65 pg/m^ but above the recommended level of 40 pg/m^.

It is our pleasure to provide these indoor air quality services to the New York City Board of Education. If yOu have any questions about this report, please call (212) 353-8280, extension 261 or 212.

Sincerely, A TCASSOCIA TES INC.

James R. Cohn, CIH, CSP Regional Manager Industrial Hygiene Division

Attachment

CONFIDENTIAL, CITY_21MC100_003471798 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000245397

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000245397Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →