NYC 9/11 Public Portal Document
ATC ASSOCIATES, INC
104 E 25th Street, 10th Floor
New York, NY 10010
Tel. 212-353-8280
Fax 212-353-8306
REPORT DATE: 02-15-02
CLIENT: NYC BOE
PROJECT ADDRESS: P. S. 89M/201 Warren St.
New York, NY 10282
PROJECT NO: 41617-0562
SAMPLED BY: M. Medinets
SAMPLE DATE: 02-14-02
DATE RECEIVED: 02-14-02
DATE ANALYZED: 02-14-02
SAMPLE MEDIA: Dust Wipe Sample
ANALYSIS REQUIRED: Method EPA 3050/7420
ANALYSIS RESULTS
SAMPLE BATCH SAMPLE DESCRIPTION LEAD DETECTION
ID NO. CONCENTRATION LIMIT
(Hg/fO
01 9672 1st Floor Hallway East of Cafeteria Floor 145.8 9.0
02 9672 1st Floor Hall - South of Cafeteria (Floor) <9.0 9.0
03 9672 Cafeteria Floor <9.0 9.0
04 9672 Auditorium Floor 99.6 9.0
05 9672 Classroom #226 (North Side Ventilators Units) Floor <9.0 9.0
06 9672 Classroom #306 (East Side Unit Ventilators) Window Sill 501.2 5.0
07 9672 Classroom #202 (South Side Unit Ventilators) Floor 16.5 9.0
08 9672 2nd Floor Hallway South End. Floor 50.3 9.0
09 9672 4th Floor Hallway •• South End Floor 14.8 9.0
10 9672 Gymnasium Floor <9.0 9.0
11 9672 Blank <9.0 9.0
NOTE 1:
THE REPORTING LIMIT (RL) IS 18.0 gg
NOTE 2:
HUD Guidelines for final clearance dust wipe samples: Floor 40 ug/ftl Window sills 250 pg/ft^
Window wells 400 pg/ft\ Exterior surfaces 800 pg/ftl
CONFIDENTIAL, CITY_21MC100_003471631
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000245267