NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 2 pages

Asbestos fiber analysis, PS 89M, PS 89M (PS 89M 201

Machine-extracted title · confidence 37%

Asbestos TEM analysis performed on PS 89M playground samples at Warren Street.

NYC-WTC_000244961–000244962
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Attn; Mr. Bernard Orlan Received: 4/7/02 7:00:00 PM N.Y.C. Board of Education ATC Group#: 7353 28-11 Queens Plaza North Analysis Date: 4/8/02 Long Island City, NY 11101

Fax: (212)475-4122 Phone: (212) 477-8941

Project; P.S. 89M, 201 Warren St., NY, NY

Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) Performed by EPA 40 CFR Part 763 Final Rule (AHERA) Analytical Asbestos /Ifen Non Asbestos # Structures Sensitivity Concentration Sample yoliime Analyzed Asb Type(s} d.Sfi-5 Sfi (S/cc) (S/mm-‘) (S/cc) Notes

08 1920.00 0,0450 0 None Detected 0 0 0.0045 <22.24 <0.0045 7353 -5

09 1920.00 0.0450 0 None Detected 0 0 0.0045 <22.24 <0.0045 7353 -9

10 1920.00 0.0450 0 None Detected 0 0 0.0045 <22.24 <0.0045 7353 -13

1 ! 1920.00 0.0450 0 None Detected 0 0 0.0045 <22.24 <0.0045 7353 -11

12 1920.00 0.0450 0 None Detected 0 0 0.0045 <22.24 <0.0045 7353 -

1920.00 0.0450 0 None Detected 0 0 0.0045 <22.2A- <0.0045 7351 -13

14 1920.00 0.0450 0 None Detected 0 0 0.0045 <22.24 <0.0045 7353 -15

!5 1920-00 0,0450 0 None Detected 0 0 0.0045 22.24 <0.0045 7.153 -15

16 1920.00 0,0450 0 None Detected 0 0 0.0045 <22.24 <0.0045 7353 -16

MICHAEL GORYCKI MICHAEL A. GORYCKf. Ph.D

Analyzed by: Approved by:

Disclaimer: The laboratory is not responsible for data reported in siructures/cc, which is dependent on volume collected by non-laboratory personnel. This lab is only responsible for data reported in structures/mmT This report rriay not be reproduced, except in full, without written approval by ATC Associates Inc, This report may not be used to claim product endorsement by NVLAP or any other agency of the U.S, Sovemment. This reports relates only to the samples reported above. Quality control data (inducing 95% confidence limits and laboratory and analysis' accuracy and precision) is available upon request.

.Accredited for NVLAP PLM/TEM #101187-0, NY State ELAP #10879

Pciye 2 <1/2

CONFIDENTIAL, CITY_21MC100_003470884 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000244962

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000244962Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

TEM data, PS 89M, May 2002

NYC-WTC_000313043

Asbestos TEM analysis of air samples collected at PS 89M playground.

Similar indexed content

Compare copies and versions →