NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

Asbestos TEM analysis, school site, Oct 2001

Machine-extracted title · confidence 42%

TEM analysis of asbestos fiber with SAED/EDS at a school site; includes dates and TEM sample details.

NYC-WTC_000244760
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N.Y. State SLAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Leng Island City, NY 11101 Report Date: lO/23/Ol

ASBESTOS FIBER /ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fib^r Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS] Method: /jHERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 19B7

Analysis Parameters

ProjecC/Site: New Stuwesant H.S., 345 Chambers St., NY, NY TEM Sample No.; 573£ 61943 Exterior 6: Interior of Building & Roof Date Rece^ived: '-0/22/01 Grid Openings Analyzed:__ 4

Project Siariiple No. :_e Average Grid Opening: 106.00 um

Air Voluire; 1956 liters Total Area Analyzed: 0.0450 mm2

Filter Type: MCE 25 mm diam.. Pore Size: 0.45 um Analytical Sensitivity :22^2 s/mm2 Effective Area: 3 8 5 mni2 0044

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fiber.-:; Bundles Clusters Struct. Struct > = 5um Struct/mm2 Struct/cc nom/mS

Chrysotile Asbestos 0 0 0 0 0 0 0.C 0.0000 0

Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Ambiguous 0 0 0 0 0 0 0.0 o.ooco 0

Total asbestos {includes ambiguous structures] 0 0 0. 0 o.ooco C Non-Asbestos 0 0 0 0 0 0 0.0 o.oooc N/A No Identification 0 0 0 0 0 0 0.0 o.oooc N/A

Total.*; (All Structures ' 0 0 0.0 O.OOOC N/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type; None detected

The .Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by.- Report Reviewed by:

Roman Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CONFIDENTIAL, CITY_21MC100_003470309 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000244760

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000244760Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000244360

TEM asbestos analysis of exterior of Neu Stuyvesant High School building, Oct 2001.

Similar indexed content

NYC-WTC_000244496

TEM analysis with SAED/EDS; project NSHS-EIR-10/14-08 at New Stuyvesant H.S.

Similar indexed content

Asbestos air sampling results, NYC DOE site, Oct 2001

NYC-WTC_000188712

Laboratory report detailing asbestos fiber analysis by transmission electron microscopy for air samples collected at a New York City Department of Education site in October 2001.

Similar indexed content