NYC-WTC_000293641
TEM analysis of exterior/interior samples for New Stuyvesant High School, Oct 2001.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗TEM analysis; exterior of building; sample 5739; opening and air volume data.
NYC-WTC_000244757OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
ATC Environmental, Inc. 104 East 25th Street New York, New York 10010
N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/23/01
ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method; AHERA Final Rule, 2PA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October .30, 1987
Sample IdenticicaLion Analysis Parameters
Project/Site: New Stuy^esan.: F.S., 345 Chambers St., NY, NY TEM Sample No.; 5739 61 94 0 Exterior S; r or of Building & Roof Date Received: 10/22/01 Grid Openings Analyzed:__ 4
Project Sample No.:_5 Average Grid Opening: 106.00 um
Air Volume: ^193€2h^ers Total Area Analyzed : 0;0450 mm2
Filter Type: MCE 25 mm diam., Pore Size: 0.45 um Analytical Sensitivity :^2^^2 s/mm2 Effective Aren; 365 mm2 0.0044 s/cc
FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single-! Matrix Total. Struct. Filter Air Fiberr Bundles Clusters Struct. Struct > = 5um Struct/mm2 Struct/cc nqm/m3
Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Amphibole Asbestos Cl 0 0 0 0 0 0. 0 0.0000 0
Ambiguous 0 0 0 0 0 0. 0 0.0000
Total asbestos (includes ambrguous structures) 0 0 0.0 0.0000 0 Non-Asbestos 0 C 0 0 0 0. 0 0.0000 N/A No Identification c 0 0 0 0 0 0, 0 0.0000 N/A
Totals (Ail Structures) 0 0 0. 0 0.0000 N/A The estimated uncertainty cf this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected
The Analysis was carried out in accordance with the approved TEM method. This laboratory i.s in compliance with the quality specified for the method.
Analyzed by; Report Reviewed by:
Ronan Peysakbov Michael A. Gorycki, Ph.D. Director of Electron Microscopy
CONFIDENTIAL, CITY_21MC100_003470306 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000244757
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000293641
TEM analysis of exterior/interior samples for New Stuyvesant High School, Oct 2001.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270879
TEM analysis; exterior/interior of building, sample 12.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293856
Asbestos TEM analysis parameters for New Stuyvesant HS exterior/interior; Oct 2001.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000188684
Laboratory report detailing asbestos fiber analysis by TEM for air samples from a NYC Board of Education building.
6 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293815
TEM analysis with SAED/EDS for New Stuyvesant H.S., Oct 2001.
6 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270759
TEM asbestos analysis with SAED/EDS identifications for New Stuyvesant High School exterior/interior.
6 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270545
TEM asbestos analysis with AHERA method for New Stuyvesant H.S.; lists sample numbers and date.
5 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000292756
TEM report with sample 5785, exterior/interior details, for New Stuyvesant H.S., 10/28/01.
6 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293859
Asbestos TEM analysis parameters for New Stuyvesant HS exterior/interior; Oct 2001.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000188679
Laboratory report documenting asbestos fiber analysis by transmission electron microscopy for a high school site in October 2001.
5 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000248323
TEM asbestos analysis with SAED/EDS for New Stuyvesant H.S., exterior/interior of building, received 10/26/01.
7 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000248379
TEM asbestos analysis with SAED/EDS for project site, Oct 1957.
7 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000293641
TEM analysis of exterior/interior samples for New Stuyvesant High School, Oct 2001.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270879
TEM analysis; exterior/interior of building, sample 12.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293856
Asbestos TEM analysis parameters for New Stuyvesant HS exterior/interior; Oct 2001.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000188684
Laboratory report detailing asbestos fiber analysis by TEM for air samples from a NYC Board of Education building.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293815
TEM analysis with SAED/EDS for New Stuyvesant H.S., Oct 2001.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270759
TEM asbestos analysis with SAED/EDS identifications for New Stuyvesant High School exterior/interior.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
TEM analysis of exterior/interior samples for New Stuyvesant High School, Oct 2001.
Similar indexed content
TEM analysis; exterior/interior of building, sample 12.
Similar indexed content
Asbestos TEM analysis parameters for New Stuyvesant HS exterior/interior; Oct 2001.
Similar indexed content
NYC-WTC_000188684
Laboratory report detailing asbestos fiber analysis by TEM for air samples from a NYC Board of Education building.
Similar indexed content
TEM analysis with SAED/EDS for New Stuyvesant H.S., Oct 2001.
Similar indexed content