TEM TEM, New Stuyvesant HS, Oct 2001

Machine-extracted title · confidence 28%

TEM analysis with SAED/EDS; exterior & interior samples, received date.

NYC-WTC_000244755
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date; 10/23/01

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method; fHERA Final Rule, SPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987

Sample Identification Analysis Parameters

Project/Site: New Stuyvesanc H.S., 345 Chambers St., KY, NY TEM Sample Ko.; 573S 61938 Exterior k Itt of Buildinq i Roof Date Received: 10/22/01 Grid Openings Analyzed:__ 4

Project Sample No. : 3 Average Grid Opening ;l^)^00 um

Air Volune: 1936 liters Total Area Analyzed: 0.0450 mm2

Filter Type: MCE 25 mm diarr.. Pore Size: 0.45 um Analytical Sensitivity; 22.2 s/rrm2 Effective Areu : 385 mrn2 C.0044 s/cc

FIB.ROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct > = 3um Struct/mTTi2 Struct/cc ngm/m3

Chrysotile Asbestos 0 0 0 0 0 0 0. c 0.0000 0

Amphibole Asbestos 0 0 0 0 0 0 o.c 0.0000 0

Ambiguous 0 0 0 0 0 0 o.c 0.0000 0

Total asbestos {inc?.ude5i ambiguous structures) 0 0 o.c 0.0000 0 Non-Asbestos 0 0 0 0 0 0 0.C 0.0000 N/A No Identification 0 0 0 0 0 0 0.c 0.0000 N/A

Totals (All 5)tructures) 0 0 0.c 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type; None detected

The .Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance' with the quality specified for the method.

Analyzed by; Report Reviewed by;

ROiTian Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CONFIDENTIAL, CITY_21MC100_003470304 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000244755

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000244755Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000270916

TEM-based asbestos fiber analysis for New Stuyvesant High School, Oct 2001.

Similar indexed content

NYC-WTC_000270539

TEM asbestos analysis for exterior/interior of New Stuyvesant H.S.; includes sample numbers and date.

Similar indexed content

NYC-WTC_000294024

TEM analysis focusing on fiber diffraction and EDS results for site samples.

Similar indexed content

NYC-WTC_000294019

Asbestos fiber TEM analysis performed for New Stuyvesant High School project sample.

Similar indexed content

Compare copies and versions →