NYC 9/11 Public Portal Document
ATC Environmental, Inc.
104 East 25th Street
New York, New York 10010
N.Y.C. Board of Education Approved N.Y. State ELAP #10879
28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187
Long Island City, NY 11101 Report Date: 10/23/01
ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM)
With Fiber Identification oy Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS)
Method; AHSR7i Final Rule, DFA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987
Sample Identification Analysis Parameters
Project/Site; New Stuyvesant H.S., 34S Chambers St., NY, NY TEM Sample No.; 5739 61936
Extero-or £ I?11erior of Building & Roof
Date Received: 10/22/01 Grid Openings Analyzed:__ 4
Project Sample No.: 1 Average Grid Opening: 106.PC um
Air Velum.? :J^9281iters Total Area Analyzed : C' . 0450 .mm2
Filter Tyi^e : MCE 25 mm digr ., Pore Size: 0.45 urn Analytical Sensitivity: 22.2 s/mm2
Effective Aret ; 3 95 mrn2 0.0Q44 S/CC
FIBROUS PARTICULATES TV^ALYZED
Number Observed CONCENTRATION
Total
Single Matrix Total. Struct. Filter Air
Fibers Bundles Clusters Struct. Struct >=5um Struct /mrr.2 Struct/cc nqm/m3
Chrysotile Asbestos 0 0 0 0 0 0 0.c C .0000 0
Amphibole Asbestcs 0 0 0 0 0 0 0.0 0.0000 0
Ambiguous 0 0 0 0 c 0 0.0 0.0000 0
Total asbe;stos (includes atrbiguous structures) 0 0 0.0 0.0000
Non-Asbestos 0 0 0 0 0 0.0 0.0000 N/A
No Identification 0 0 0 0 0 0.0 0.0000 N/A
Totals (All Structures) 0 0 0. 0 0 . C000 N/A
The estimE.ted uncertainty of this analysis is 1 standard deviation.
Non-asbestos fib« i.d. (EDS/SAED): None detected
Amphibole Asbestos Type: None detected
The Jinalysis was carried out in accordance with the approved TEM method.
This laboratory is in compliance with the quality specified for the method.
Analyzed by: Report Reviewed by;
Roman Peysakhov Michael A. Gorycki, Ph.D.
Director of Electron Microscopy
CONFIDENTIAL, CITY_21MC100_003470302
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000244753
OCR can misread numbers and units. Confirm readings against the page image before using them.