Asbestos TEM analysis, New Stuyvesant H.S., Oct 2001

Machine-extracted title · confidence 25%

TEM SAED/EDS analysis; exterior/interior of building; sample 5737, received 10/21/01.

NYC-WTC_000244728
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010 N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date; 10/22/01 ASBESTOS FIBER 7iNALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification oy Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDSt Method: ArlERA Final Rule, NPA Federal Register (40 GFR, Part 763), Vol. 52, No. 210, October 30, 1987

Sample Identification AnaJj/sisPar^rrieters

Proiect/Site: New Stuw€jsant H 345 Chambers St.. NY, NY TEM Sample No.: 5737 61837 Exterior & Ii cerior of Buildinc & Roof Date Received ;_10/^20£ Grid Openings Analyzed:__4

Project Sample No.: 16 Average Grid Opening: 106. PC um

Air Volumti: 1920 liters Total Area Analyzed: 0.0450 mm2

Filter Ty})e MCE 25 mm dian . , Pore Size: 0.45 um Analytical Sensitivity:22..^2 s2mm^ Effective Arec : 385 mm2 0.0045 s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total single Matrix Total. struct. Filter Air Fibers Bundles Clusters Struct. Struct >=5ura Struct/mn';2 Struct/cc r.arr./m3

Chrysotile^ Asbestos 0 0 0 0 0 0 0.0 C . 0000 0

Amphibole Asbestos 0 0 0 0 0 0 o.c 0.0000 0

Ambiguous 0 0 0 0 0 0 o.c 0.0000 0

Total asbe;stcis (includes ambiguous structures) 0 0 0.0 0.0000 0 Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N7A No Identification (3 0 0 0 0 0 0.0 0.0000 N/A

Totals (All Structures) 0 0 0.0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fib'= i . d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by-. Report Reviewed by.

Marek Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CONFIDENTIAL, CITY_21MC100_003470271

SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000244728

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000244728Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000274122

TEM analysis of asbestos fibers, SAED/EDS, New Stuyvesant H.S., Oct 2001.

Similar indexed content

NYC-WTC_000293689

TEM asbestos analysis of New Stuyvesant H.S. samples, including SAED/EDS data.

Similar indexed content

NYC-WTC_000270379

TEM asbestos analysis report for exterior/interior of building, Oct 2001.

Similar indexed content

Compare copies and versions →