NYC 9/11 Public Portal Document
ATC Environmental, Inc.
104 East 25th Street
New York, New York 10010
N.Y.C. Board of Education Approved N.Y. State ELAP #10879
28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187
Long Island City, NY 11101 Report Date: 10/22/01
ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM)
With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Enercy-L’ispersive X-RAY Spectroscopy (EDs;
Method: AHEItA Final Rule, J PA Federal Register (40 CFR, Part 0631, Vol. .52, No. 210, October 30, 1987
Sample Identificacior. Analysis Parameters
Project/Site: New Stuyvesant H.S., 345 Chambers St.., NY, NY TEM Sample No.: 5737 61834
Exterior & Int€■ rior of Building & Roof
Date Received; 10/21/01 Grid Openings Analyzed:__4
Project Sample No.:_13 Average Grid Opening: 106.00 urn
Air Voluni(i: 1928 liteis Total Area .Analyzed: C.O450 mm2
Filter Tyjie; MCE 2 5 mm dian . , Pore Size: 0.45 um Analytical Sensitivity: 22.2 s/mm2
Effective Area : ,3 5 5 mm2 0.0044 s/cc
FIBROUS PARTICULATES ANALYZED
Number Observed CONCENTRATION
Total
Single Matrix Total. Struct. Filter Air
Fibers Bundles Clusters Struct. Struct >=5um Struct/mrr.2 Struct/cc nqm/m3
Chrysotile Asbestos 0 0 0 0 0 0.0 0.0000 c
Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Ambiguous 0 0 0 0 0 0 0.0 0.0000 c
Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0
Non-Asbescos 0 0 0 0 0 0 0.0 0.0000 N/A
No Identification 0 0 0 0 c 0 0.0 0.0000 N/A
Totals (All Structures) 0 0 0.0 0.0000 N/A
The estimcted uncertainty of this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED); None detected
Amphibole Asbestos Type: None detected
The Analysis was carried out in accordance with the approved TEM method.
This laboratory is in compliance with the quality specified for the method.
Analyzed by: Report Reviewed by;
Mai'ek Peysakhov Michael A. Gorycki, Ph.D.
Director of Electron Microscopy