NYC 9/11 Public Portal Document
ATC Environmental, Inc.
104 East 25th Street
New York, New York 10010
N.Y.C, Board of Education Approved N.Y. State ELAP #10879
28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187
Long Island City, NY 11101 Report Date; 10/22/01
ASBESTOS FIBER ANALYSIS.BY TRANSMISSION ELECTRON MICROSCOPY (TEM)
With Fiber Identification by Selected-Area Electron Diffraction iSAEDl and Energy-Dispersive X-RAY Spectroscopy (EDS)
Method: AHERA Final Rule, SPA Federal Register (40 CFR, Part 763), Vol. 52, No. 21C, October 30, 1987
Sample Identification Analysis Parameters
Project/Site; New Stuyvesan'. F.S., 345 Chambers St., NY, NY TEM Sample No.: 5737 61833
Exterior S: Interior of Building & Roof
Date Received; 10/21/01 Grid Openings Analyzed:__4
Project Sample No,: 12 Average Grid Opening: 106. QC urn
Air Vc1urn2: 1928 liters Total Area Analyzed :0^;.£45£mm2
Filter Ty^e: MCE 25 mm diam., Fore Size: 0.45 uiri Analytica1 Sensitivity: 22.2 £/mm2
Effective Arer: 385 mm2 0 ■ 0044 s/cc
FIBROUS PARTICULATES ANALYZED
Number Observed CONCENTRATION
Total
Single Matrix Total. Struct. Filter Air
Fibers Bundles Clusters Struct. Struct >=5uiTi Struct/miTi2 Struct/cc nam/m3
Chryscitilt? Jisbestos 0 0 0 0 0 0 0.0 0.0000
Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 C
Ambiguous 0 0 0 0 0 0 0.0 0.0000 0
Total asbfistos (includes an.biguous structures) 0 0 0.0 0.0000 0
Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A
No Identification 0 0 0 0 0 0 0.0 O.COOO N/A
Totals (All Structures) 0 0 0.0 0.0000 N/A
The estimc.ted uncertainty of this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED): None detected
Amphibole Asbestos Type: None detected
The Analysis was carried out in accordance with the approved TEM method.
This laboratory is in compliance with the quality specified for the method.
Analyzed by; Report Reviewed by:
Marek Peysakhov Michael A. Gorycki, Ph.D.
Director of Electron Microscopy
CONFIDENTIAL, CITY_21MC1OO_OO347O267
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000244725