NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

Asbestos TEM analysis, New Stuyvesant H.S., Oct 2001

Machine-extracted title · confidence 42%

TEM asbestos analysis with SAED/EDS for New Stuyvesant High School, Oct 2001.

NYC-WTC_000244686
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-1.1 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/21/01 ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification :y Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy [EDS’ Method: AlERJx Final Rule, DPA Federal Register [40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987

Sample Ide:iti£ication Analysis Parameters

Project/Site: New Stuyvesant H.S., 345 Chambers St., NY, NY TEN Sample No.: 5735 61732 Various Sites Inside and Outside the Building Date Received: 10/20/01 Grid Openings Analyzed:__ 4

Project Sample No.: 18 Average Grid Opening: 106.00 um

Air Volume-1928 liters Total Area Analyzed ;£^9450 rnrn2

Filter Tyjie : MCE 25 mm dian . , Pore Size: 0.45 um Analytical Sensitivity: 22.2 s/mm2 Effective Ares: 385 mm2 0 . 0044 s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers .BLindles ClustersStruct^Struct >c5um Struct/mm2 Struct/cc ncm/m3

Chrysctile; Asbestos 0 0 0 0 0 0 0,0 0.0000 0

Amphibole Asbestos 0 C 0 0 0 0 0.0 0.0000 0

Ambiguous 0 C 0 0 0 C 0.0 0.0000 0

Total asbcistos (includes ambiguous structures) 0 C 0.0 0.0000 C Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A No Identification 0 0 0 0 0 0 0.0 0.0000 N/'A

Totals (All Structures) 0 0 C.0 0.0000 N/A The estim.itec uncertainty cf this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by;

Ronan Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CONFIDENTIAL, CITY_21MC100_003470225 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000244686

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000244686Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000244677

TEM asbestos analysis at New Stuyvesant High School, Oct 2001.

Similar indexed content

NYC-WTC_000293736

TEM analysis of asbestos at New Stuyvesant High School, Oct 2001.

Similar indexed content

NYC-WTC_000244687

TEM asbestos analysis with SAED/EDS for New Stuyvesant High School, Oct 2001.

Similar indexed content

NYC-WTC_000293726

TEM analysis of New Stuyvesant HS samples; includes air volume and opening data.

Similar indexed content

Compare copies and versions →