NYC 9/11 Public Portal Document
ATC Environmental, Inc.
104 East 25th Street
New York, New York 10010
N.Y.C. Board of Education Approved N.Y. State ELAP #10879
28-1.1 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187
Long Island City, NY 11101 Report Date: 10/21/01
ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM)
With Fiber Identification :y Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy [EDS’
Method: AlERJx Final Rule, DPA Federal Register [40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987
Sample Ide:iti£ication Analysis Parameters
Project/Site: New Stuyvesant H.S., 345 Chambers St., NY, NY TEN Sample No.: 5735 61732
Various Sites Inside and Outside the Building
Date Received: 10/20/01 Grid Openings Analyzed:__ 4
Project Sample No.: 18 Average Grid Opening: 106.00 um
Air Volume-1928 liters Total Area Analyzed ;£^9450 rnrn2
Filter Tyjie : MCE 25 mm dian . , Pore Size: 0.45 um Analytical Sensitivity: 22.2 s/mm2
Effective Ares: 385 mm2 0 . 0044 s/cc
FIBROUS PARTICULATES ANALYZED
Number Observed CONCENTRATION
Total
Single Matrix Total. Struct. Filter Air
Fibers .BLindles ClustersStruct^Struct >c5um Struct/mm2 Struct/cc ncm/m3
Chrysctile; Asbestos 0 0 0 0 0 0 0,0 0.0000 0
Amphibole Asbestos 0 C 0 0 0 0 0.0 0.0000 0
Ambiguous 0 C 0 0 0 C 0.0 0.0000 0
Total asbcistos (includes ambiguous structures) 0 C 0.0 0.0000 C
Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A
No Identification 0 0 0 0 0 0 0.0 0.0000 N/'A
Totals (All Structures) 0 0 C.0 0.0000 N/A
The estim.itec uncertainty cf this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED): None detected
Amphibole Asbestos Type: None detected
The Analysis was carried out in accordance with the approved TEM method.
This laboratory is in compliance with the quality specified for the method.
Analyzed by: Report Reviewed by;
Ronan Peysakhov Michael A. Gorycki, Ph.D.
Director of Electron Microscopy
CONFIDENTIAL, CITY_21MC100_003470225
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000244686
OCR can misread numbers and units. Confirm readings against the page image before using them.