NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

Asbestos TEM analysis, New Stuyvesant HS, Oct 2001

Machine-extracted title · confidence 42%

TEM asbestos analysis with SAED/EDS for New Stuyvesant High School, Oct 2001.

NYC-WTC_000244674
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/21/01

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED: and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AKERA Final Rule, E-^A Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987

£^ample Identification 7malysis Parameters

Project/Site: New Stuyvesant H.5., 345 Chambers St., NY, NY TEM Sample No.: 5735 61719 Various Sites Inside and Outside the Building Date Received Grid Openings Analyzed:__ 4

Project Sample No.:_5 .Average Grid Opening: 106.00 urri

Air Volume: 1952 liters Total Area .Analyzed :0 i.04,50 rnm2

Filter Ty^je: MCE 25 mm diam. Pore Size : 0.45 um Analytical Sensitivity: 22.2 s/mm2 Effective Aree; 365 mm2 0 ■ 0044

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATOON Total S ing le­ Matrix Total. Struct. Filter Air Fobert Bundles Clusters Struct. Struct > = 5um st ruct /wn2 Struct/cc nqm/m3

Chrysotile Asbestos () 0 0 0 D 0 0.0 0.0000 0

Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000

Ambiguous 0 0 0 0 0 0 0. c 0.0000 0

Total asbestos {includes ambiguous structures) 0 0 0.0 o.ccoo 0 Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A No Identification 0 0 0 0 c 0 0.0 0.0000 N/A

Totals (Ml Structures) 0 C 0.0 C . 0000 N/A The estimated uncertarnty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laborator-y is in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by:

Roman Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CONFIDENTIAL, CITY_21MC100_003470212 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000244674

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000244674Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000270580

TEM asbestos identification by SAED/EDS for air samples at New Stuyvesant High School.

Similar indexed content

NYC-WTC_000293726

TEM analysis of New Stuyvesant HS samples; includes air volume and opening data.

Similar indexed content

NYC-WTC_000293733

TEM analysis for asbestos identification at New Stuyvesant High School, Oct 2001.

Similar indexed content

NYC-WTC_000293696

TEM asbestos analysis of New Stuyvesant H.S. samples, including SAED/EDS results.

Similar indexed content

Compare copies and versions →