NYC-WTC_000248282
TEM/SAED/EDS asbestos analysis for New Stuyvesant High School exterior/interior.
6 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗TEM asbestos analysis using SAED/EDS for New Stuyvesant High School; sample and project data.
NYC-WTC_000244649OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
ATC Environmental, Inc. 104 East 25th Street New York, New York 10010
N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Flaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/20/01
ASBESTOS FIBER gj^ALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification cy Selected-Area Electron Diffraction (SAED) and Energ>’-Dispersive X-RAY Spectroscopy 'EDS) Method: AIERA Final Rule, DPA Federal Register (40 CFR, Part 763}, Vol. 52, No. 210, October 30, 1987
Sample ication Analysis Parameters
Project/Site: New Stuyvesant H.S.,, 345 Chambers St., NY, NY TEM Sample No.: 5730 61713 Various Sites' inside and Outside the Building Date Rece-tved: 10/19/01 Grid Openings Analyzed:__4
Project Sample No.:_22 Average Grid Opening :l 0£j 0p i^
Air VolunK?: 1976 liters Total Area Analyzed: C.0450 mmS
Filter Ty})e: MCE 25 mm dian., Pore Size: 0.45 um Analytical Sensitivity: 22■2 s/mm2 Effective Aree.: 385 .mm2 0.0043 s/cc
FIBROUS PARTICULATES ANALYZED Number Ctsero^ed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fiberf Bundles Clusters Struct. Struct >-5um Struct /'mrr.2 Struct/cc nam/m3
Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Ambiguous 0 C 0 0 0 0 o.c 0.0000 0
Total asb€istos (includes ar.biguous structures) 0 0 o.c 0.0000 0 Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A No Identification 0 0 0 0 0 0 0.0 0.0000 N/A
Totals (Aj.1 Structures.) 0 0 0.0 0.0000 N/A The estimeited uncertainty cf this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type; None detected
The /analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.
Analyzed by: Report Reviewed by:
Roman Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy
CONFIDENTIAL, CITY_21MC100_003470183 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000244649
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000248282
TEM/SAED/EDS asbestos analysis for New Stuyvesant High School exterior/interior.
6 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000185596
Laboratory report detailing transmission electron microscopy and EDS analysis of asbestos fibers from a New York City Board of Education building.
4 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000240477
Summary of TEM results for Stuyvesant H.S. with NVLAP/DOH accreditation.
6 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293732
TEM asbestos analysis for site New Stuyvesant High School, Oct 2001.
6 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270625
TEM analysis of asbestos fibers at Stuyvesant High School, SAED/EDS details included.
6 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293937
TEM analysis results for exterior/interior air samples at New Stuyvesant HS, 10/25/01.
6 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293971
TEM analysis; exterior/interior of building; date 10/26/01.
6 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000294069
TEM asbestos analysis with SAED/EDS at Stuyvesant H.S., Oct 2001.
6 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270719
Asbestos fiber analysis by TEM for New Stuyvesant High School, received 12/22/01.
5 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000294050
TEM analysis parameters; sample 5609; AHERA/EDS references.
6 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000248341
TEM asbestos fiber analysis; New Stuyvesant HS; exterior/interior; SAED/EDS; received 10/22/01; analyzed 10/28/01.
6 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293726
TEM analysis of New Stuyvesant HS samples; includes air volume and opening data.
5 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000248282
TEM/SAED/EDS asbestos analysis for New Stuyvesant High School exterior/interior.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000185596
Laboratory report detailing transmission electron microscopy and EDS analysis of asbestos fibers from a New York City Board of Education building.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293732
TEM asbestos analysis for site New Stuyvesant High School, Oct 2001.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270625
TEM analysis of asbestos fibers at Stuyvesant High School, SAED/EDS details included.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293937
TEM analysis results for exterior/interior air samples at New Stuyvesant HS, 10/25/01.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293971
TEM analysis; exterior/interior of building; date 10/26/01.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000248282
TEM/SAED/EDS asbestos analysis for New Stuyvesant High School exterior/interior.
Similar indexed content
NYC-WTC_000185596
Laboratory report detailing transmission electron microscopy and EDS analysis of asbestos fibers from a New York City Board of Education building.
Similar indexed content
NYC-WTC_000240477
Summary of TEM results for Stuyvesant H.S. with NVLAP/DOH accreditation.
Similar indexed content
TEM asbestos analysis for site New Stuyvesant High School, Oct 2001.
Similar indexed content
NYC-WTC_000270625
TEM analysis of asbestos fibers at Stuyvesant High School, SAED/EDS details included.
Similar indexed content