NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

Asbestos TEM fiber analysis, H.S., Oct 2001

Machine-extracted title · confidence 25%

TEM asbestos analysis with SAED/EDS identifications for New York High School project.

NYC-WTC_000244607
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/18/01 ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With FibEr Identification ay Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy !EES) Method: AHERJs Final Rule, KPA Federal Register 140 CFR, Part 7G3), Vol. 52, No. 210, October 30, 1987

Sample Identification Analysis Parameters

Project/Site: New Stuyvegant H.S., 345 Chambers St., NY, NY TEM Samole No.: 5725 61646 Exterior i Interior of Building & Roof Date Received; id Openings Analyzed:__4

Project Sample No.: 14 Average Grid Opening :J^0 6;0C£m

Air Volume :I92£r;ter£ Total Area Analysed: 0.0450 mm2

Filter Tyoe: MCE 25 mm diam., Pore Size: 0.45 um Analytical Sensitivity: 22.2 s,/mrn2 Effective Arei: 0.0044 s/cc

FIBROUS PARTICULATES TINALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers bundles Clusters Struct. Struct > = Sum St ruct/mm2 Struct/cc ncfm/m3

CxTrysotile Asbestos C 0 0 0 0 0 0. 0 0.0000 0

Amphibole Asbestos 0 0 0 0 0 0 0.0 0. 0000 0

Ambiguous C 0 0 0 0 0 0.0 0 . 0000 0

Total asbestos (includes anhiguous structures) 0 0 0.0 0.0000 Non-Asbestos C 0 0 0 0 0 0.c 0 . 0000 N/A No Identification C 0 0 0 0 0 0.0 0.0000 N,'A

Totals (All Structures; 0 0 0.0 0.0000 N,'A The estimated uncertainty c.f this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by:

Michael A. Gorycki, Ph.D. Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CONFIDENTIAL, CITY_21MC100_003470130 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000244607

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000244607Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000293768

TEM-based asbestos analysis with SAED/EDS for exterior/interior of building.

Similar indexed content

NYC-WTC_000274166

TEM asbestos analysis; New Stuyvesant HS, sample 5758-62157, received 10/24/01.

Similar indexed content

NYC-WTC_000293853

Asbestos TEM analysis parameters for New Stuyvesant HS exterior/interior; Oct 2001.

Similar indexed content

NYC-WTC_000274108

Asbestos fiber TEM analysis report for New Stuyvesant High School building site, Oct 2001.

Similar indexed content

Compare copies and versions →