NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

Asbestos TEM analysis, Nev. Stuyvesant H.S., Oct 2001

Machine-extracted title · confidence 58%

TEM/EDS results for New Stuyvesant High School building samples, Oct 2001.

NYC-WTC_000244602
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NX^LAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/18/01 ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification cy Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy 'EDS': Method: AHERA Final Rule, UFA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October JO, 1987

Sample Identification Analysis Parameters

Project/Siie; New Stuyvesant H.S., 345 Chambers St., NY, NY TEM Sample Me.: 5725 61640 Exterior & Interior of Building &. Roof Date Received: lO/ie/01 Grid Openings Analyzed:__ 4

Project Sample No.: 08 Average Grid Opening :10£^£0 jjm

Atr Volume; 2 920 liters Total Area Analyzed: O.045C nim2

Filter Type . MCE 25 mm dian . , Fore Size-. 0.45 um Ana 1 ytica 1 Sensitivity22.2 s/mm2 Effsetivp Are;- 385 mm2 0.0045 s/cc

FIBROUS PARTICULATES 7\NALYZED Number Cbserv^ed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct >=5uni Struct/mm2 Struct/cc nam/m3

Chrysotile Asbestos 0 0 0 0 0 C .0 C .0000 0

Amphibole Asbestos 0 0 0 0 0 0.0 0.0000 c

Ambiguous 0 0 0 0 c 0 0.0 C . 0000 0

Total asbesto.3 (includes ambiguous structures) 0 0 0. 0 0.0000 0 Ncn-Asbestos 0 0 0 0 0 a o.c 0.0000 N/A Nc Identification 0 0 0 0 0 0 o.c 0.0000 N/A

Totals (All Structures) 0 0 Q.0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by; Report Reviewed by-.

Michael A. Gorycki, Ph.D. Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CONFIDENTIAL, CITY_21MC100_003470124 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000244602

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000244602Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000244419

TEM asbestos fiber analysis performed for New Stuyvesant High School site, October 2001.

Similar indexed content

NYC-WTC_000244420

TEM asbestos analysis with SAED/EDS for New Stuyvesant High School site, October 2001.

Similar indexed content

NYC-WTC_000244518

TEM analysis with SAED/EDS for New Stuyvesant H.S. exterior/interior; Oct 2001.

Similar indexed content

NYC-WTC_000244614

Asbestos fiber analysis by TEM with SAED/EDS for exterior/interior building areas at a HS site, received Oct 18, 2001.

Similar indexed content

Compare copies and versions →