ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/18/01 A5EE5TO,S FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEMj W.ith Fiber Identification by Selected-Area Electron Diffraction [SAED) and Energy-Dispersive X-rtAY Spectroscopy (EDS) Method; AHERA Final Rule?, IPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1967

Sample Identicic£tion Analysis Parameters

Prcject/Site: New Stu\^5sant K.S., 345 Chambers St., NY, NY TEM Sample No,: 5716 61541 Exterior k Interior of Building « Roof

Date Received :_1_O/12Z21 Grid Openings Analyzed;__ 4

Project Sample No.: NSHS-E IP-10/17 - 9 Average Grid Opening : 1^06;00 um

Air Velum? ; 1 899 1ite^ Total Area Analyzed :0;0 45 C)jni^

Filtei' Ty:oe : MCE 25 mrr, dram., Pore Size: 0.45 urn Analytical Sensitivity; 22.2 s/mm2 Effective Are/i :3f5nTm2 0.0045 s/cc

FIBROLTSPARTICULATESANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. .Struct > = 5um Struct/mm2 Struct/cc nqm/m3

Chrysotile? Asbestos 0 0 0 0 □ 0 0,0 0.0000 0

Amphibole Asbestos C: 0 0 0 0 0 0.0 0.0000 0

Ambiguous 0 0 0 0 0 0 0. 0 0.0000 0

Total asbestos (includes an.btguous structures) 0 0 0.0 0.0000 c Non-Acbest;os C 0 0 0 0 0 0.0 0.0000 N/A No Identification 0 0 0 0 0 0.0 0.0000 N/A

Totals (All Structures 0 0 0.c 0.0000 N/A Ths estimatet uncertainty of this analysis is 1 standard deviation

Non-assbestos fiber i.d. (EDS/SAED) : None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by; Report Reviewed by:

Marek Peysakbov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CONFIDENTIAL, CITY_21MC100_003470101 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000244579

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000244579Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000244754

TEM analysis details: SAED, EDS, exterior/interior building samples, receiving date.

Similar indexed content

NYC-WTC_000248381

TEM asbestos analysis with SAED/EDS for New Stuyvesant H.S., Oct 2001.

Similar indexed content

Compare copies and versions →