ATC Environmental, Inc. 104 East 25th Street New York, New York 10010 N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/18/01 ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (ED.S) Methcd; AHER.A Final Rule, .ERF Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987

Sample Identification Analysis Farametert

Project/Site: New Stuwesanr H.S., 345 Chambers St., NY, NY TEM Sample No.: 5716 61539 Exterior & Interior of Building & Roof Date riece ivec ■. lO/n/O: Grid Openings Analyzed:__ 4

Project Sample No.: NSHS-E~R-IC/l7-7 Average Grid Opening ;106;00 um

Air Volume Total Area Analyzed ;0;^04 50 mm2

Filter Type; MCE 25 mm dian., Fore Size: 0.45 urn Analyt real Sensitivity : 22.2 s/rnm2 Effective Axee : 385 mm2 0.0045 s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct > = 5um Struct ^mm2 £truct/cc nqm/m3

Chrysotile Asbestos 0 0 0 0 0 0 0.0 0 . 0000 c

Amphibole Asbestos 0 0 0 0 0 0 C,0 0 . 0000 c

Ambiguous 0 0 0 0 0 0 0.0 0.0000 0

Total asbesto.s (includes ambiguous structures) C 0 0.0 0 .0000 0 Non-Asbestos 0 0 0 0 0 0 o.c 0.0000 N/A No Identification 0 0 0 0 0 0 0.0 0.0000 N/A

Total.g (All Structures) 0 0 0.0 0.0000 K/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED); None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by; Report Reviewed by:

Marek Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CONFIDENTIAL, CITY_21MC1OO_OO347OO99 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000244577

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000244577Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000244523

TEM asbestos analysis of exterior/interior samples at New Stuyvesant High School, Oct 2001.

Similar indexed content

NYC-WTC_000293518

TEM-based asbestos fiber analysis for New Stuyvesant High School site, Oct 2001.

Similar indexed content

Compare copies and versions →