NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

TEM analysis, NSHS-EIR-10/17-4

Machine-extracted title · confidence 38%

TEM analysis details of New Stuyvesant HS site, Oct 2001.

NYC-WTC_000244574
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010 N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/18/01

ASBESTOS FIBERANALYSISBY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fib.sr Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS' Method: ZxHERZ^ Final Rule, EPA Federal Register (40 CFR, Part 763', Vol. 52, No. 210, October 30, 1937

Sample Ide'Ht ification Analysis Parameters

Proj ect/Si te .- New Stuwesani E . .9 . , 345 Chambers St., NY, NY TEM Sample No.: 5710 61536 Exterior Interior of Building & Rcof Date Received: 10/17/01 Grid Openings Analyzed:__4

Project 5ample No.: NSHS-EIR-10/17-4 Average Grid Opening :l££^00 um

Air Volurr.e: 1899 liters Total Area Tinalyzed: 0.0450 mm2

Filter Type: MCE 25 mm dian. Pore Size: 0.45 um Analytical Sensitivity : 22.2 s/mrr,2 Effective Are 3: 385 mm2 0 . CiQ15 s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Singl? Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct > = 5um Struct/mm2 Struct/cc ncnTi/m3

Chrysotile Asbestos 0 0 ■ 0 0 0 0 n,o 0.0000

Amphibole Asbestos 0 0 0 0 0 0 0.0 0.oooo

Ambiguous 0 0 0 0 0 0 0.0 0.0000

Total asksstos (includesi ambiguous structures) 0 0 D.O 0.0000 0 Non-Asbestos 0 0 0 0 0 0 0.0 0.oooc N/A No Identification 0 0 0 0 0 0 0.0 0.0000 N/A

Totals (All Structures) 0 0 0.0 0.0000 K/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by:

Marek Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CONFIDENTIAL, CITY_21MC1OO_OO347OO96 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000244574

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000244574Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000244427

TEM asbestos analysis with SAED/EDS for New Stuyvesant High School site, October 2001.

Similar indexed content

Compare copies and versions →