ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1167 Long Island City, NY 11101 Report Date: 10/16/01

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fibtir Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: ?HERA Final Rule, SPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987

Sample Identification Analysis Parameters

Project/Site: New Stum^esant H.S., 345 Chambers St., NY, NY TEM Sample No.: 5709 61440 Exterior ft IdterLor of Building & Roof Date Received: 10/16/01 Grid Openings Analyzed-.__4

Project Sample No. : KSHS-EIR-10/16-7 Average Grid Opening: 106.00 um

Air Velum-:: :1926 1ite^ Total Area Analyzed;n,i.0£52 nm2

Filter Tyoe : MCE 25 mm diatn. , Pore Size: 0.45 urn Analytical Sensitivity:__22.^2—2Z212i2 Effective Area: 365mrn2 0.0044

FIBROUS PARTICULATESANALYZED Number Observed CONCENTRATION Total Single- Matrix Total. Struct. Filter Air Fibers Bundles Clusters struct. Struct >=5uni Struct/mm2 Struct/cc ncfm/tn3

Cnrysotil€; /asbestos 0 C 0 0 0 0 0.0 0 , 0000 0

Amphibole Asbestos 0 C 0 0 0 0 0.0 0.0000 0

Ambiguous 0 0 0 0 c 0 o.c 0.0000 0

Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0 Non-Asbestos 0 0 0 0 0 0 0.0 O.COOQ N/A No Identification 0 0 0 0 0 0.0 0. 0000 N/A

Totals (All Structures) 0 0 0.0 0.0000 N/^A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by:

Roman Peysakhov Michael A. Gcrycki, Ph.D. Director of Electron Microscopy

CONFIDENTIAL, CITY_21MC100_003470066 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000244545

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000244545Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000244597

Asbestos fiber analysis by TEM for New Stuyvesant High School site, Oct 2001.

Similar indexed content

NYC-WTC_000293500

TEM asbestos analysis for exterior/interior samples; New Stuyvesant High School; received 10/13/01.

Similar indexed content

Compare copies and versions →