NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

Asbestos TEM analysis, [site], Oct 1987

Machine-extracted title · confidence 22%

TEM asbestos analysis; exterior/interior of building; Received Oct 16, 01 (likely 2001) with 5709 sample.

NYC-WTC_000244544
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmencal, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Leng Island City, NY 11101 Report Date: 10/16/01

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fibsr Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive'X-RAY Spectroscopy (EDS; Method; /iHERA.Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987

Sample Ideintification .j^alysis Paramecers

Project/Site: Nev Stux^esant H.5., 345 Chambers St., NY, NY TEM Sample No.: 5709 ei439 Exterior .2 Interior of Building &. Roof Date Rece'ived: '-0/16/01 Grid Openings Analyzed:__ 4

Project S:ample No. : NSHS>EIR-10/16-6 Average Grid Opening: 106.00 urn

Ail Volume :191TUj;£rs Total Area Analyzed :0;04^,^nim2

Filter Type: MCE 25 mm diaii. Pore Size: 0.45 um Analytical Sensitivity: 22.2 s/mm2 Effective Are.4: 385 mm2 0.0045 s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. struct. Filter Air Fiber.s Bundles Clusters Struct. Struct > = 5um Struct/mm2 Struct/cc ngm/m3

Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Amphibole Asbestos 0 0 0 0 0 0 0 . f) o.oooc 0

Ambiguous 0 0 0 0 9 0 0.0 0.0000 0

Total asbestos (includes ambiguous structures) 0 0 0,0 0.0000 0 Non-Asbes cos 0 0 0 0 0 0 0.0 0.0000 N/A No IdentiEicaoion 0 0 0 0 0 0 0.0 0.0000 N/A

Totals (All Structures; 0 0 0.0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by; Report Reviewed by:

Ronan Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CONFIDENTIAL, CITY_21MC1OO_OO347OO65 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-\/VTC_000244544

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000244544Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000244370

TEM asbestos fiber analysis with SAED and EDS, New Stuyvesant High School, Oct 2001.

Similar indexed content

NYC-WTC_000244496

TEM analysis with SAED/EDS; project NSHS-EIR-10/14-08 at New Stuyvesant H.S.

Similar indexed content

Compare copies and versions →