NYC 9/11 Public Portal Document
ATC Environmental, Inc.
104 East 25th Street
New York, New York 10010
N.Y.C. Board of Education Approved N.Y. State ELAP #10879
28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187
Long Island City, NY 11101 Report Date: 10/16/01
ASBESTOS FIBER /lNALYSIS BY TRTiNSMISSION ELECTRON MICROSCOPY (TEM)
With Fiber Identification by Selected-Area Electron Diffraction (SAEDi and Energy-Dispersive X-RAY Spectroscopy (EDS)
Method: Final Rule, iPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987
Sample Identification Analysis Parameters
Project /Site: New^tuyves^.: H 345 Chambers St., NY, NY TEM Sample No.: 5696 61342
Exterior S: Interior of Building & Roof
Date Received:__lC215Zki Grid Openings Analyzed:__ 4
Project Sample No.: NSHS-EER-10/15 - 09 Average Grid Opening : l 0^^0.C uni
Air Volums; 1908 liters Total Area Analyzed: 0,0450 rnm2
Pi Iter Type; MCE 25 mtn diam. , Pore Size: 0.45 urn Analytical Sensitivity: 22.2 s/mmS
Effective Aren: 385 mm2 0.0045 s/cc
FIBROUS PARTICULATES ANALYZED
Number Observed CONCENTRATION
Total
Single Matrix Total. Struct. Filter Air
Fibers Bundles Clusters Struct. Struct >^5um Struct/mm2 Struct/cc nqtn/m3
Chrysotile Asbestos C; 0 0 0 0 0 0,0 0.OODO 0
Amphibole Asbestos 0 0 G 0 0 0 0.0 0.OODO 0
Ambiguous C 0 0 0 0 0 0.0 0.0000 c
Total asbestos (includes ambiguous structures) 0 C 0.0 0.0000
Non-Asbestos 0 0 0 0 0 c 0.0 C.0000 K/A
No Identification 0 0 0 0 0 0 0.0 C . 0000 N/A
Totals (A..1 Structures) 0 0 C.0 0.0000 N/A
The estimated uncertainty cf this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED): None detected
Amphibole Asbestos Type: None detected
The Analysis was carried out in accordance with the approved TEM method.
This leiboratory is in compliance with the quality specified for the method.
Analyzed by: Report Reviewed by;
Marek Peysakhov Michael A. Gorycki, Ph.D.
Director of Electron Microscopy
CONFIDENTIAL, CITY_21MC100_003470040
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000244522