ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM)
With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive y-F;AY Spectroscopy (EDS:
Method: AHERJi Final Rule, KPA Federal Register (40 GFR, Part 763), Vol. 52, No. 210, October 30, 1987
Sample Identification Analysis Parameters
?roject/Sile: New Stux^esant.H.£., 345 Chambers St., NY, NY TEN Sample No.: 5698 61339
Exterior & Interior of Building & Roof
Date 3<ece Lvec.: 10/15/01 Grid Openings Analyzed;_ 4
Project Sample No.: NSHS>e:R-10/15-06 Average Grid Opening: 106.CO um
Air Volume:1390 liters Total Area Analyzed :0^045C nuTi2
Filter Tyi7e MCE 25 mm dian ., Pore Size: U.45 um Analytical Sensitivity; 22.2 s/mm2
Effective Aiec: 385 mm2 C.0045 s/cc
FIBROUS PARTICULATES ANALYZED
Number Observed CONCENTRATION
Total
Single Matrix Total. Struct, Filter Air
Fibers Bundles Clusters Struct. Struct >=5um St ruct/mm2 Struct/cc n gm/tn 3
Chrysotile; Asbestos 0 0 0 0 0 0 0.0 0 . 0000 0
Amphibole Asbestos 0 C 0 0 0 0 0.0 0.0000 0
Ambiguous 0 0 0 0 0 0 c.o 0 .0000 0
Total asbestos {includes arr.biguous structures) 0 0 0.0 0.0000 0
Non-Asbest.os 0 0 0 0 0 0 0.0 0.0000 N/A
No Identification 0 0 0 0 0 0 0.0 0.0000 N/A
Totals {Ail Structures) 0 0 0.0 G . 0000 N/A
The estimaxed uncertainty cf this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED): None detected
Amphibole Asbestos Type: None detected
The Imalysis was carried out in accordance with the approved TEM method.
This laboratory is in compliance with the quality specified for the method.
Aneilyzed by: Report Reviewed by:
Marek Peysakhov Michael A. Gorycki, Ph.D.
Director of Electron Microscopy
CONFIDENTIAL, CITY_21MC100_003470037
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000244519