NYC-WTC_000244767
TEM asbestos analysis with SAED/EDS; New Stuyvesant H.S. project details and sample number.
7 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗TEM analysis with SAED/EDS; project NSHS-EIR-10/14-09 data.
NYC-WTC_000244498OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
ATC Environmental, Inc. 104 East 25th Street New York, New York 10010
N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/15/01
ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fibsr Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: JiHERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987
Sample Id^intification Analysis Parameters
Project/Site: New Stuyveaan: H.3., 345 Chambers St., NY, NY TEM Sample No.: 5691 6 1077 Exterior oc Interior of Building & Roof Date Rece^ived: lO/lB/Ol Grid Openings Analyzed:__4
Project Sample No.: NSHS-EIR-10/14-09 Average Grid Opening .•l£6.^00 nm
Air Voluire: IS&O. liters Total Area Analyzed: 0.0450 mm2
Filter Tyne: MCE 2 5 mm diarn., Pore Size: 0.4 5 urn Analytical Sensi t ivity .•22^2 sAnm2 Effective Are^; 3BS mm2 0.0045 s/cc
FIBROUS PARTICULATES AXALYZHD Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air F.iberu bundles Clusters Struct . Struct >^5um Struct/mm2 Struct/cc ngm/m3
Chrysotile Asbestos 0 0 0 0 0 0 0,0 0.0000 c
Amphibole Asbestos 0 0 0 0 0 0.0 0.0000 0
Ambiguous 0 O' 0 0 0 0.0 0.0000 0
Total asbestos (includes ambiguous structures) 0 0 0.0 0 . 0000 Non-Asbe3t;os C 0 0 0 0 0 0.0 0.0000 N/A No Identification C 0 0 0 0 0 0.0 0.0000 N/A
Totals:. (Ail Structures) 0 c 0.0 0.0000 N/A The estimated uncertainty cf this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected
The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.
Analyzed by: Report Reviewed by:
.Roman Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy
CONFIDENTIAL, CITY_21MC100_003470013 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000244498
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000244767
TEM asbestos analysis with SAED/EDS; New Stuyvesant H.S. project details and sample number.
7 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000176450
ATC Environmental report on asbestos fiber analysis by TEM for exterior and interior samples collected at a school at 345 Chambers Street.
6 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000244758
TEM analysis: exterior & interior of building; sample 5739; opening and air volume data.
7 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000244575
TEM analysis details for NSHS EIR, Oct 2001.
6 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000244757
TEM analysis; exterior of building; sample 5739; opening and air volume data.
7 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000244339
TEM analysis by SAED/EDS for asbestos at Stuyvesant High School exterior; includes sample 5629.
8 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293518
TEM-based asbestos fiber analysis for New Stuyvesant High School site, Oct 2001.
7 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270680
TEM analysis of asbestos fibers; SAED/EDS identification, New Stuyvesant H.S., Oct 2001.
7 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000244501
TEM-based asbestos identification and SAED/EDS analysis for building samples, Oct 2001.
6 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000244452
TEM analysis for NSHS EIR; exterior/interior building areas, 10/13/01 deliveries.
6 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000248341
TEM asbestos fiber analysis; New Stuyvesant HS; exterior/interior; SAED/EDS; received 10/22/01; analyzed 10/28/01.
8 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000240477
Summary of TEM results for Stuyvesant H.S. with NVLAP/DOH accreditation.
8 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000244767
TEM asbestos analysis with SAED/EDS; New Stuyvesant H.S. project details and sample number.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000176450
ATC Environmental report on asbestos fiber analysis by TEM for exterior and interior samples collected at a school at 345 Chambers Street.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000244758
TEM analysis: exterior & interior of building; sample 5739; opening and air volume data.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000244575
TEM analysis details for NSHS EIR, Oct 2001.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000244757
TEM analysis; exterior of building; sample 5739; opening and air volume data.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000244339
TEM analysis by SAED/EDS for asbestos at Stuyvesant High School exterior; includes sample 5629.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000244767
TEM asbestos analysis with SAED/EDS; New Stuyvesant H.S. project details and sample number.
Similar indexed content
NYC-WTC_000176450
ATC Environmental report on asbestos fiber analysis by TEM for exterior and interior samples collected at a school at 345 Chambers Street.
Similar indexed content
TEM analysis: exterior & interior of building; sample 5739; opening and air volume data.
Similar indexed content
NYC-WTC_000244575
TEM analysis details for NSHS EIR, Oct 2001.
Similar indexed content
TEM analysis; exterior of building; sample 5739; opening and air volume data.
Similar indexed content