ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date; 10/14/Cl

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction iSAED! and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: ?IIERA Final Rule, !3PA Federal Register (40 CFR, Part 763), Vol. 52, No. 21C, October .30, 1987

Sample Identificg-tipn Analysis Parameters

Project/ Site; New Stuwesant K.S., 345 Chambers St.. NY, NY TEM Sample No.: .5687 61C58 Exterior L tr11erior of Building & Roof Date Received: 10/14/01 Grid Openings Analyzed:_ 4

Project Sample No. : NSH£-EIR-IC/13 - 05 Average Grid Opening: 106. PC um

Air Volume: 1908 liteJ's Total Area Analyzed :C;04.5C jnm2

Fi 11er Ty|>e : MCE 25 mm dian , , _.Pore_S_izej_0_;_45_jim Ariaiyt i ca 1 Sens itivity: 22.2 s / mm2 Effective Aree: 385 mm2 C.0045 s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct . Struct >s5um Struct/mm2 Struct/cc nqm/m3

Cnrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Ambiguous 0 0 0 c 0 0 0.0 0.0000 0

Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0 Non-Asbestos 0 0 0 0 0 0 0.0 0,0000 N/A No Identification 0 0 0 0 0 0 0. 0 0.0000 N/A

Totals (All Structures) 0 0 0.0 0.0000 N/A Ths estimaied uncertainty oi this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by; Report Reviewed by:

Roman Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CONFIDENTIAL, CITY_21MC100^003469981

SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000244471

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000244471Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000244757

TEM analysis; exterior of building; sample 5739; opening and air volume data.

Similar indexed content

NYC-WTC_000293621

TEM asbestos fiber analysis of exterior and interior building samples from New Stuyvesant High School, Oct 2001.

Similar indexed content

Compare copies and versions →