NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

TEM TEM report, NSHS-SRR-10/13-03

Machine-extracted title · confidence 45%

TEM analysis of NSHS exterior/interior air sample; SAED/EDS data.

NYC-WTC_000244470
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010 N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED Ni^LAP Lab Code # 1187 Leng Island City, NY 11101 Report Date: lO/14/oi

ASBESTOS FIBER Ai;iALYSI5 BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method; ZiBERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987

Sample Identification Analysis Parameters

Project/Site: New Stuywesant H.S,, 345 Chambers St., NY, NY TEM Sample No.: 5687 61056 Exterior £<. interior of Building & Roof Cate Received; 10/14/01 Grid Openings Analyzed:__ 4

Project Sample No. : NSHS-SRR-10/13 - 03 Average Grid Opening :106.;00 um

Air Vo1ums: 1908 liters Total Area Analyzed: 0.0450 mm2

Filter Type: MCE 25 mm c'ian. , Pore Size: 0-45 um Analytical Sensitivity;22;2 s2TnTn2 Effective Arei; 385 mm2 0.0Q45 s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct Struct >=5um Struct/nim2 Struct/cc nqm/tr3

Chrysotile: Asbestos 1 0 0 0 0 0 0.0 0.oooo 0

Amphibole Asbestos C 0 0 0 0 0 0.0 0.0000 0

Ambiguous 0 0 0 0 0 0 0.0 o.oooc D

Total asbestos (includes ambiguous structures) 0 0 0. 0 0.0000 0 Ncr.-Asbestos t) 0 0 0 0 0 U. 0 0.0000 N/A No Identification 0 0 0 0 0 0 0. 0 0.0000 N/A

Totals (All Structures) 0 0 0.0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with, the approved TEM method. This laboratory ;.s in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by:

Roman Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CONFIDENTIAL, CITY_21MC100_003469979

SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000244470

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000244470Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000248318

TEM asbestos analysis with SAED/EDS for New Stuyvesant High School, exterior/interior of building, received 10/26/01.

Similar indexed content

NYC-WTC_000244419

TEM asbestos fiber analysis performed for New Stuyvesant High School site, October 2001.

Similar indexed content

NYC-WTC_000244518

TEM analysis with SAED/EDS for New Stuyvesant H.S. exterior/interior; Oct 2001.

Similar indexed content

NYC-WTC_000244614

Asbestos fiber analysis by TEM with SAED/EDS for exterior/interior building areas at a HS site, received Oct 18, 2001.

Similar indexed content

Compare copies and versions →