NYC 9/11 Public Portal Document
ATC Environmental, Inc.
104 East 25th Street
New York, New York 10010
N.Y.C. Board of Education Approved N.Y. State ELAP #10879
28-11 Queens Plaza North ACCREDITED Ni^LAP Lab Code # 1187
Leng Island City, NY 11101 Report Date: lO/14/oi
ASBESTOS FIBER Ai;iALYSI5 BY TRANSMISSION ELECTRON MICROSCOPY (TEM)
With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS)
Method; ZiBERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987
Sample Identification Analysis Parameters
Project/Site: New Stuywesant H.S,, 345 Chambers St., NY, NY TEM Sample No.: 5687 61056
Exterior £<. interior of Building & Roof
Cate Received; 10/14/01 Grid Openings Analyzed:__ 4
Project Sample No. : NSHS-SRR-10/13 - 03 Average Grid Opening :106.;00 um
Air Vo1ums: 1908 liters Total Area Analyzed: 0.0450 mm2
Filter Type: MCE 25 mm c'ian. , Pore Size: 0-45 um Analytical Sensitivity;22;2 s2TnTn2
Effective Arei; 385 mm2 0.0Q45 s/cc
FIBROUS PARTICULATES ANALYZED
Number Observed CONCENTRATION
Total
Single Matrix Total. Struct. Filter Air
Fibers Bundles Clusters Struct Struct >=5um Struct/nim2 Struct/cc nqm/tr3
Chrysotile: Asbestos 1 0 0 0 0 0 0.0 0.oooo 0
Amphibole Asbestos C 0 0 0 0 0 0.0 0.0000 0
Ambiguous 0 0 0 0 0 0 0.0 o.oooc D
Total asbestos (includes ambiguous structures) 0 0 0. 0 0.0000 0
Ncr.-Asbestos t) 0 0 0 0 0 U. 0 0.0000 N/A
No Identification 0 0 0 0 0 0 0. 0 0.0000 N/A
Totals (All Structures) 0 0 0.0 0.0000 N/A
The estimated uncertainty of this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED): None detected
Amphibole Asbestos Type: None detected
The Analysis was carried out in accordance with, the approved TEM method.
This laboratory ;.s in compliance with the quality specified for the method.
Analyzed by: Report Reviewed by:
Roman Peysakhov Michael A. Gorycki, Ph.D.
Director of Electron Microscopy
CONFIDENTIAL, CITY_21MC100_003469979
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000244470