NYC-WTC_000244754
TEM analysis details: SAED, EDS, exterior/interior building samples, receiving date.
7 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗TEM analysis using SAED/EDS for NSHS EIR site; includes sample volumes and openings.
NYC-WTC_000244449OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
ATC Environmental, Inc. 104 East 25th Street New York, New York 10010
N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/13/01
ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification oy Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS; Method; AHERA Final Ru„e, DPA Federal Register (40 CFR, Part 763;, Vol. 52, No. 210, October 50, 1987
Sample Identification Analysis Parameters
Pro j ec t: / S i : e ; New Stux^esant. H.S., 345 Chambers St., NY, NY TEM Sample No.: 5676 61046 Exterior & lt.terior of Building & Roof Date Received; 10/13/01 Grid Openings Analysed;__ 4
Project Sample No.: N5HS-E1R-10/12-08 Average Grid Opening : 106^£0 j^
Air Volum.;: I908 liters Total Area Analyzed.- C . 0450 mm2
Filter Tyoe: MCE 25 mm diam. Pore Size; 0.45 um Analytical Sensitive ty : 22^^2 s2nn^ Effective Area: 385 mm2 0.0045 s/cc
FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct >=5urTi Struct/mm2 Struct/cc nam/m3
Chrysotile Asbestos 0 0 0 0 0 0 C.0 0.0000 0
Amphibole Asbestos 0 0 0 0 0 0 C.0 0.0000 0
Ambiguous 0 0 0 0 0 0 c.o 0 . 0000 0
Total asbe:stos {includes anbiguous structures) 0 0 c.o 0 . 0000 0 Non-Asbest;o£! 0 0 0 0 0 0 0.0 0.0000 N/A No Identification 0 0 0 0 0 0 0.0 0.0000 N/A
Totals (All Structures) 0 0 0.0 0.0000 N/A The estimated uncertainty cf this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected
The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.
Aneilyzed by: Report Reviewed by:
Marek Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy
CONFIDENTIAL, CITY_21MC100_003469956 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000244449
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000244754
TEM analysis details: SAED, EDS, exterior/interior building samples, receiving date.
7 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000244731
TEM SAED/EDS; exterior & interior of building; sample 5737; received 10/21/01.
7 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000248339
TEM asbestos fiber analysis for exterior/interior of building; SAED/EDS; New Stuyvesant HS; received 10/27/01; analyzed 10/28/01.
6 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000248381
TEM asbestos analysis with SAED/EDS for New Stuyvesant H.S., Oct 2001.
7 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000188684
Laboratory report detailing asbestos fiber analysis by TEM for air samples from a NYC Board of Education building.
6 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000244425
TEM asbestos analysis of exterior/interior at New Stuyvesant High School, October 2001.
6 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000292756
TEM report with sample 5785, exterior/interior details, for New Stuyvesant H.S., 10/28/01.
6 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000248323
TEM asbestos analysis with SAED/EDS for New Stuyvesant H.S., exterior/interior of building, received 10/26/01.
7 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293864
TEM asbestos analysis for exterior/interior of building; includes opening and area measurements; received 10/23/01.
7 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293641
TEM analysis of exterior/interior samples for New Stuyvesant High School, Oct 2001.
7 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000244757
TEM analysis; exterior of building; sample 5739; opening and air volume data.
7 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293518
TEM-based asbestos fiber analysis for New Stuyvesant High School site, Oct 2001.
6 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000244754
TEM analysis details: SAED, EDS, exterior/interior building samples, receiving date.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000244731
TEM SAED/EDS; exterior & interior of building; sample 5737; received 10/21/01.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000248339
TEM asbestos fiber analysis for exterior/interior of building; SAED/EDS; New Stuyvesant HS; received 10/27/01; analyzed 10/28/01.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000188684
Laboratory report detailing asbestos fiber analysis by TEM for air samples from a NYC Board of Education building.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000244425
TEM asbestos analysis of exterior/interior at New Stuyvesant High School, October 2001.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000292756
TEM report with sample 5785, exterior/interior details, for New Stuyvesant H.S., 10/28/01.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
TEM analysis details: SAED, EDS, exterior/interior building samples, receiving date.
Similar indexed content
TEM SAED/EDS; exterior & interior of building; sample 5737; received 10/21/01.
Similar indexed content
NYC-WTC_000248339
TEM asbestos fiber analysis for exterior/interior of building; SAED/EDS; New Stuyvesant HS; received 10/27/01; analyzed 10/28/01.
Similar indexed content
TEM asbestos analysis with SAED/EDS for New Stuyvesant H.S., Oct 2001.
Similar indexed content
NYC-WTC_000188684
Laboratory report detailing asbestos fiber analysis by TEM for air samples from a NYC Board of Education building.