ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/13/01

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fibeir Identification tv Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method; TiFERA Pinal Rule, ERA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987

Sample Idertificat.ion Analysis Parameters

Project/Site: New Stuyvesant H.S., 345 Chambers St., NY, NY TEM Sample No.; 5676 61C43 Exterior^^ In7erior of Building & Roof Date Received Grid Openings Analyzed:__4

Project Sample No.; NSHS-EIR-10/12-05 Average Grid Opening: 106.00 urn

Air Volume: 1890 liters Total Area 7malyzed:0;045 0 jTim2

Filter Type: MCE 25 mm diam. Pore Size; 0.45 urn Analytical Sensitivity:22jJ s/mm2 Effective Area: 385 mm2 0 ■ 0045 s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct ;> = 5um Struct/mm2 Struct/cc nom/mS

Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Ambiguous 0 0 0 0 0 0 0.0 0.0000 0

Total asbestos (tncludes ambiguous structures) 0 0 0.0 0.0000 0 Non-Asbestos 0 0 0 0 0 0,0 0.0000 N/A No Identification 0 0 0 0 0 0.0 0.0000 N/A

Totals (All Structures) 0 0 0.0 0.0000 N/A The estimt.ted uncertainty cf this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Ansilyzed by: Report Reviewed by;

Marek Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CONFIDENTIAL, CITY_21MC100_003469953 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000244446

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000244446Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000270516

TEM asbestos identification and diffraction/EDS analysis for New Stuyvesant High School, 10/01.

Similar indexed content

NYC-WTC_000293591

Asbestos fiber analysis by TEM with SAED and EDS for New Stuyvesant H.S.

Similar indexed content

NYC-WTC_000293525

TEM asbestos analysis for NSHS, Oct 14, 2001.

Similar indexed content

NYC-WTC_000270486

TEM analysis of exterior/interior of New Stuyvesant HS; AHERA method.

Similar indexed content

Compare copies and versions →