NYC 9/11 Public Portal Document
ATC Environmental, Inc.
104 East 25th Street
New York, New York 10010
N.Y.C. Board of Education Approved N.Y. State ELAP #10879
28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187
Long Island City, NY 11101 Report Date; 10/12/01
ASBESTOS FIBER ANALYSIS BY TRTkNSMISSION ELECTRON MICROSCOPY (TEM)
With Fiber Identification joy Selected-Area Electron Diffraction (SAEDl and Energy-Dispersive X-RAY Spectroscopy ;edS:
Method; ANERA Final Rule, EPA Federal Register (40 CFR, Part 763;, Vol. 52, No. 210, October 30, 1987
Sample Identifica~ion Analysis Parameters
Project/Sice: New Stuyvesant H.S., 345 Chambers St., NY, NY TEN Sample No.: 5668 60936
Exterior Ir,ts:rior of Building & Roof
Date Received: lO/ll/o; Grid Openings Analyzed;_ 4
Project Sample No.: NSES-ElR-10/11-09 Average Grid Opening: 106. PC um
Air Volume: 1890 liters Total Area TUialvzed: 0.045C mm2
Filter Tyj)e: MCE 25 mm dian ., Pore Size: 0.45 um Ana 1yticai Sensitivity; 22.2 s/mm2
Effective Aree: 385 mm2 C ■ 0045 5/cc
FIBROUS PARTICULATES ANALYZED
Number Observed CONCENTRATION
Total
Single Matrix Total. Struct. Filter Air
Fibers Bundles Clusters Struct. Struct > = 5um Struct/mm2 Struct/cc nqm/m3
Chrysotile Asbestos 0 0 0 0 0 0 0. 0 0.0000 0
Amphibole Asbestos 0 0 0 0 0 0 0. 0 0.0000 0
Ambiguous 0 0 0 0 0 0 0.0 0.0000 0
Total asbestos (includes anbiguous structures) 0 0 0.0 0.0000 G
Non-Asbestos c 0 0 0 0 0 0.0 0.0000 N/A
No Identicication 0 0 0 0 0 0.0 0.0000 N/A
Totals (All Structures 0 0 0.0 0.0000 N/A
The estimated uncertainty of this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED): None detected
Amphibole Asbestos Type: None detected
The Analysis was carried out in accordance with the approved TEM method.
This laboratory is in compliance with the quality specified for the method.
Analyzed by: Report Reviewed by:
Roman Peysakhov Michael A. Gorycki, Ph.D.
Director of Electron Microscopy
CONFIDENTIAL, CITY_21MC100_003469929
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000244424