NYC 9/11 Public Portal Document
ATC Environmental, Inc.
104 East 25th Street
New York, New York 10010
N.Y.C. Board of Education Approved N.Y. State ELAP #10879
28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187
Leng Island City, NY 11101 Report Date; lO/lO/Ol
ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM)
With Fibix Identification toy Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS'
MethC'd: 7iHERA Final Rule, EFA Federal Register (40 CFR, Part 763', Vol. 52, No. 210, October 3C.. 1987
Sample Ide^ntification Analysis Parameters
Project/Site: Nev Stuyvesant H.S., 345 Chambers St., NY, NY TEM Sample No.: 5662 60811
Exterior Interior of Building & Roof
Date Received: 10/10/01 Grid Openings Analyzed:__4
Project Sample No.: NSHS-EIR-lO/10-12 Average Grid Opening: 106.00 um
Air Volume: 1917 liters Total Area Analyzed ; 0.;04,5.0 rnrn2
Filter Type: MCE 25 mm diani. , Pore Size: 0.45 um Analytical Sensitivity : 22.2 s/inni2
Effective Arei.: 385 mm2 0 . 0045 s/cc
FIBROUS PARTICULATES TkNALYZED
Number Observed CONCENTRATION
Total
Sdnglc' Matrix Total. Struct. Filter Air
Fibers Bundles Clusters Struct. Struct > = 5um Struct/mm2 Struct/cc nqm/in3
Chrysotile! Asbestos 0 C 0 0 0 c 0.0 0,0000 c
Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 c
Ambiguous 0 0 0 0 0 C .0 0.0000 0
Total asbestos (includes amciguous structures) C 0 0.0 0.0000 0
Nor.-As be st os 0 0 0 0 C 0 0.0 0.0000 N/A
No Identification 0 0 0 0 0 0 0.0 0.0000 N/A
Totals {All Structures) 0 0 0.0 0.0000 N/A
The estimated uncertainty ot this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED): None detected
Amphibole Asbestos Type: None detected
Ths Analysis was carried out in accordance with the approved TEM method.
This laboratory is in compliance with the quality specified for the method.
Analyzed by; Report Reviewed by-.
Marek Peysakhov Michael A. Gorycki, Ph.D.
Director of Electron Microscopy
CONFIDENTIAL, CITY_21MC1OO_OO34699O5
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000244404