NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

Asbestos TEM analysis, 345 NY H.S., Oct 2001

Machine-extracted title · confidence 28%

TEM analysis and diffraction/EDS for exterior & interior of building at 345 HS, received 10/01.

NYC-WTC_000244402
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010 N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date; lO/lO/Dl ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEMi With Fiber Identification by Selected-Area Electron Diffraction iSAEDI and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: ?HERA Pinal Rule, SPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987

Sa.mple Identificacion Anal ysisPar^nieters

Project/Site: New Stu\^esanL H.S., 345 Chambers St., NY, NY TEM Samole No.: 5662 G0809 Exterior S. Interior of Building a Roof Date Received: 10/10/01 Grid Openings Analyzed:__ 4

Project Sample No. ; NSHS-EIR-IC/IQ-IO Average Grid Opening :106;0£i^

Air Volume: 1908 liters Total Area Analyzed: 0.Q45Q mm2

Filter Tyoe: MCE 25 mm diam., Fore Size: 0.45 urn Analytical Sensitivity : 22^2 s2rrim2 Effective Area; 385mm2 0.QC45 s/cc

FIBROLISPARTICULATESANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct. > = 5um Struct/mm2 Struct/cc ngm/m3

Chrysotile: Asbestos 0 0 0 0 0 0 0.0 0 , 0CC0 0

Amphibole Asbestos C 0 0 0 0 0 0.0 0.0000 0

Anbiguous 0 0 0 0 0 0 0. 0 0.0000 0

Total asbestos (includes ambiguous structures) 0 0 0. 0 0.0000 0 Non-As be s t os 0 0 0 0 0 0 0.0 0.oooo N/A No Identification 0 0 n 0 0 0 0 .0 0.0000 N/A

Totals (All Structures) 0 0 0.0 0,0000 N/A The estimated uncertainty ot this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type; None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by; Report Reviewed by;

Marek Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CONFIDENTIAL, CITY_21MC100_003469903

SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000244402

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000244402Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000248381

TEM asbestos analysis with SAED/EDS for New Stuyvesant H.S., Oct 2001.

Similar indexed content

NYC-WTC_000244492

Asbestos TEM analysis with diffraction/EDS for exterior/interior of building.

Similar indexed content

NYC-WTC_000293519

TEM asbestos identification with SAED/EDS for exterior/interior of building, Oct 2001.

Similar indexed content

Compare copies and versions →