ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date; 10/10/01

ASBES:;roSFU^ERAUALYSISBy TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAy Spectroscopy (EDS) Method: AliERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987

Sample Identification Analysis Parameters

Project/Sit;e: New Stuyvesant H.S., 345 Chambers St., NY, NY TEM Sample No.: 5662 60800 Exterior & Interior of Building & Roof Date Received :10/10210i Grid Openings Analyzed:__ 4

Project Scimple No.: NSES-EIR-10/10-01 Average Grid Opening: 106.00 urn

Air Volume: 1890 liters Total Area Analyzed: 0.0450 mm2

F liter Ty}.ie: MCE 25 mm dian . , Pore Size: 0.45 um Analytical Sensitivity Effective Area: 365 mm2 0 ■ 0045 s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct > = 5um Struct/mm2 Struct/cc ngm/m3

Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Ambiguous 0 0 0 0 0 0 0.0 0.oooc 0

Total asbestos (includes ambiguous structures} 0 0 0.0 0.0000 0 Non-Asbestos 0 0 0 0 0 0 0,0 0.oooc N/A No Identification 0 0 0 0 0 0 0.0 o.oooc N/A

Totals (All Structures) 0 0 0. 0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED); None detected Amphibole Asbestos Type; None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by; Report Reviewed by;

Marek Peysakhav Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CONFIDENTIAL, CITY_21MC100_003469894 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000244393

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000244393Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000293767

TEM asbestos fiber analysis of air samples from New Stuyvesant High School exterior/interior.

Similar indexed content

NYC-WTC_000244442

TEM analysis with SAED/EDS for New Stuyvesant High School exterior/interior samples.

Similar indexed content

TEM asbestos analysis, 5784, 10/27/01

NYC-WTC_000248352

TEM analysis of asbestos sample 5784; New Stuyvesant HS; exterior/interior; SAED/EDS; received 10/27/01; analyzed 10/27/01.

Similar indexed content

NYC-WTC_000270970

TEM asbestos analysis with SAED/EDS for New Stuyvesant HS exterior/interior, Oct 2001.

Similar indexed content

Compare copies and versions →