NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

TEM analysis, NSHS, Oct 2001

Machine-extracted title · confidence 52%

TEM asbestos analysis of exterior/interior and roof at NSHS, Oct 2001.

NYC-WTC_000244378
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmencal, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NI^LAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/09/01

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS’ Method: /BERA Final Rule, SPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987

Sample Identi£ication Analysis Parameters

Project/Site: New Stuvx-esarr: H.S., 345 Chambers St., NY, NY TEM Sample No.: 564g 60689 Exterior InLe.rior of Building & Roof D.-ate Received: 10/09/01 Grid Openings Analyzed:__ 4

Project Sample No.: N5HS-EIR-10/9-12 Average Grid Opening ;1,0 6^^00 lw

Air Volume; 1899 liters Total Area Analyzed: 0.0450 mm2

Filter Tyoe: MCE 25 mm dram., Pore Size: C.45 um Analytical Sensitivity: 22.2 s/mm2 Effective Area: 385 mm2 0 . 0045 s/cc

FIBROUS PARTICULATES TXMALYZED Number Observed CONCENTRATION Total Single; Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct > = 5uTn Struct/mm2 .St ruct/cc nQrn/m3

Ciirysotile Asbestos 0 0 0 0 0 0 0. 0 0.0000 c

Amphibole Asbestos C 0 0 0 0 0 0.0 0 . 0000 0

Ambiguous 0 0 0 0 0 c 0.0 0,0000 0

Total asbe:stos {includes anibiguous structures) 0 0 C.0 0.0000 0 Non-Asbest.OE 0 C 0 0 0 0 C. 0 0.0000 N/A No Identiiication 0 0 0 0 0 0 C.0 0.0000 N/A

Totals (All Structures) 0 0 0.0 0.0000 N/A The estime.ted uncertainty cf this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory as in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by.-

Roir.an Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CONFIDENTIAL, CITY_21MC100_003469874

SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000244378

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000244378Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000244518

TEM analysis with SAED/EDS for New Stuyvesant H.S. exterior/interior; Oct 2001.

Similar indexed content

NYC-WTC_000270714

Asbestos fiber analysis by TEM for New Stuyvesant High School, received 10/22/01.

Similar indexed content

NYC-WTC_000244614

Asbestos fiber analysis by TEM with SAED/EDS for exterior/interior building areas at a HS site, received Oct 18, 2001.

Similar indexed content

Compare copies and versions →