NYC-WTC_000244754
TEM analysis details: SAED, EDS, exterior/interior building samples, receiving date.
5 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗TEM/SAED/EDS analysis for exterior Stuyvesant High School samples; 10/08/01.
NYC-WTC_000244355OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
ATC Environmental, Inc. 104 East 25th Street New York, New York 10010
N.Y.C. Board cf Education Approved N.Y, State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/08/01
ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber _dentification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS; Method: AHER.A Final Rule, SPA Federal Register (40 CFR, Part 763), Vol, 52, No. 210, October 30, 1987
Sample Identification Analysi^Pararnet^rs
Preject/Site: New Stuyvesanz K.S., 345 Chambers St., NY, NY TEM Sample No,; 5639 6 056 6 Exterior of Ruilding & Roof Date Received; 10/08/01 Grid Openings Analyzed:__ £
Project Sample No. : NSHA-EH&R-10/8-01 Average Grid Opening
Air Volume :_19n81iteiL^ Total Area Analyzed: 9,04 50 mm2
Filter Tyoe; MCE 25 mm dram. Pore Size: C.45 um TUialytical Sensitivity :2 2^;2.s/rTTm2 Effective Aren; 3 8 5 mtnS 0. 0045 s/cc
FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct > = 5um Struct/mtr2 Struct/cc ngtn/m3
Chrysotil«? Asbestos 0 0 0 9 0 0.0 0.0000 0
Amphibole Asbestos c 0 c 0 0 0 0.0 0.0000 0
Ambiguous 0 0 0 0 0 0 0. 0 0.0000 0
Total asbestos (includes ar.bigucus structures) 0 0 0. 0 0.0000 0
Non-Asbestos C 0 0 0 0 0 0. 9 0.0000 N/A No Identification C 0 0 0 0 0 0. c 0.0000 N/A
Totals (All Structures) 0 0 0.0 0.0000 N/A The estimated uncertainty cf this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected
The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.
Analyzed by: Report Reviewed by;
Marek Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy
CONFIDENTIAL, CITY_21MC100_003469848 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000244355
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000244754
TEM analysis details: SAED, EDS, exterior/interior building samples, receiving date.
5 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000340253
TEM analysis of air samples from HS for Economics & Finance; TEM/SAED/EDS results.
4 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000248281
TEM analysis parameters for Stuyvesant High School project; SAED/EDS identifications.
5 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000244396
TEM results for exterior/interior NSHS samples, Oct 2001.
5 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000176406
Air sampling results from the exterior and interior of a high school analyzing asbestos fibers using transmission electron microscopy.
3 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000248319
TEM asbestos analysis with SAED/EDS for New Stuyvesant H.S., exterior/interior of building, received 10/27/01.
4 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000248381
TEM asbestos analysis with SAED/EDS for New Stuyvesant H.S., Oct 2001.
5 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000274123
AHERA/HS TEM asbestos analysis with SAED/EDS, New Stuyvesant H.S., Oct 2001.
5 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000248307
TEM asbestos analysis with diffraction/EDS, New Stuyvesant High School site, 10/27/01.
5 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000294143
TEM analysis details for Stuyvesant HS with diffusion and volume data.
5 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000292753
TEM parameters and air volume for exterior/interior of New Stuyvesant H.S., 10/28/01.
5 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000244757
TEM analysis; exterior of building; sample 5739; opening and air volume data.
5 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000244754
TEM analysis details: SAED, EDS, exterior/interior building samples, receiving date.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000248281
TEM analysis parameters for Stuyvesant High School project; SAED/EDS identifications.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000244396
TEM results for exterior/interior NSHS samples, Oct 2001.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000176406
Air sampling results from the exterior and interior of a high school analyzing asbestos fibers using transmission electron microscopy.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000248319
TEM asbestos analysis with SAED/EDS for New Stuyvesant H.S., exterior/interior of building, received 10/27/01.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000274123
AHERA/HS TEM asbestos analysis with SAED/EDS, New Stuyvesant H.S., Oct 2001.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
TEM analysis details: SAED, EDS, exterior/interior building samples, receiving date.
Similar indexed content
NYC-WTC_000340253
TEM analysis of air samples from HS for Economics & Finance; TEM/SAED/EDS results.
Similar indexed content
NYC-WTC_000248281
TEM analysis parameters for Stuyvesant High School project; SAED/EDS identifications.
Similar indexed content
NYC-WTC_000244396
TEM results for exterior/interior NSHS samples, Oct 2001.
Similar indexed content
NYC-WTC_000176406
Air sampling results from the exterior and interior of a high school analyzing asbestos fibers using transmission electron microscopy.
Similar indexed content