ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/06/01

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AIERA Final Rule, DPA Federal Register (40 CFR, Part 7631, Vol. 52, No. 210, October 30, 1987

Sample Ide:it.Lf ication Analys i s Parameters

Project/Si te: New Stuyvesant H.S., 345 Chambers St., NY, NY TEM Sample No.: 5623 - 60350 Exterior of Building u Roof Date Received:3d)/06/01 Grid Openings Analyzed; 4

Project Sample No.: NSHS>EBR-10/6-06 Average Grid Opening: 106.00 um

Air Volume: 1890 liters Total Area Analyzed: 0.045C nim2

Filter Tyoe: MCE 25 mm diam., Pore Size: 0.45 um Analytical Sensitivity: 22.2 s/mm2 Effective Area: 365 rntn2 0.0045 s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. struct. Filter Air Fibers Bundles Clusters Struct. Struct > = 5um Struct/mm2 Struct/cc nqrm/m3

Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Ambiguous 0 0 0 0 0 0 0.0 0.0000 0

Total asbestos (includes ainbiguous structures} 0 0 o.c 0.0000 0

Non-Asbestos 0 0 0 0 0 0 o.c 0.0000 N/A No Identification 0 0 0 0 0 0 o.c 0.0000 N/A

Totals (All Structures) 0 0 0.0 0.0000 N/A The estirrated uncertainty cf this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Tknalyzed by: Report Reviewed by.

Marek Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CONFIDENTIAL, CITY_21MC1OO_OO3469817 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000244327

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000244327Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000270916

TEM-based asbestos fiber analysis for New Stuyvesant High School, Oct 2001.

Similar indexed content

Asbestos TEM analysis, 5784, 10/28/01

NYC-WTC_000248341

TEM asbestos fiber analysis; New Stuyvesant HS; exterior/interior; SAED/EDS; received 10/22/01; analyzed 10/28/01.

Similar indexed content

Compare copies and versions →