ATC sample results, Jan–Feb 2002

Machine-extracted title · confidence 43%

Laboratory results for air samples; most below OEL with a few elevated contaminants identified.

NYC-WTC_000244080–000244082
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Liberty P Mutual

Industrial Hygiene Air Sample Results Summary for Week of 1/25/02 to 2/1/02

Attached is a summary of die laboratory results completed during the week of January 25, 2002 to Februap: 1, 2002. Tlie air samples were collected by ATC associates at the World Trade Center site.

Tlie majority of the samples collected by ATC are “personal samples”, meaning diat the worker wore die sampling device. In addition, die most of results have shown exposure levels to be below shift adjusted occupational exposure limits. The exceptions were;

• lead concentration of 242% of the shift adjusted OEL on a Torch Cutter in depression on die spot of tower 2, • An arsenic concentration of 214% of the shift adjusted OEL on a Torch Cutter in depression at tower 2, • Diesel exhaust particulate concentrations at 214% and 104% of the shift adjusted OEL on a Torch Cutter in depression at tower 2 and Grappler Operator in depression at tow'er 1, respectively, • An asbestos concentration at 198 % of the shift adjusted OEL* on a spotter on surface at 4 WTC, and • A quartz concentration of 104% of the shift adjusted OEL on a Laborer in a pit at Liberty: and W ashington Streets.

In addition, die following results are at or above 50% of die shift adjusted DEL (but below 100" ii ot the shift adjusted OEL). The opera lions associated with dicsc results should receive attention to ensure that these results are an accurate reflection of actual exposures and that feasible steps are taken in an attempt to ensure that exposures do not elevate over dme;

• Diesel exhaust particulate concentrations of 96 %, 68%, 59%, and 54% of the shift adjusted OEL on a Truck Washer at pier 25, a Truck Washer at West St., a Loader Operator in die depression, and a Spotter on the surface at pier 25, respectively, and • Asbestos concentrations of 70 % and 60% of the shift adjusted OEL on a Spotter in depression at tower 1 and Grappler Operator in tower 1,

Some of llic columns in the attached surnman- may require explanation:

AnaJyte Class - This column includes general category: of the agents (substances) which were sampled.

# of Samples - Titis indicates how many individual samples were collected for the agent class li.sted.

# of Analysis - ITtis is the number of individual analyses performed. If only one analysis is performed on each sample, then the number of analytes will equal the number of samples. I lowcvcr, most samples are analyzed for more than one agent as tollows:

' The fibers present may or may not be asbestos. This sample is being analyzed further to confirm the presence of asbestos. That result is pending.

CONFIDENTIAL INSURANCE INFORMATION, CITY_21MC100_008007964 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000244080

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000244080Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →